ED310e Indoor Dome
12
4.2.13 MOTION: ON / OFF selectable.
MOTION DET: ON
DETECT SENSE
000~127
BLOCK DISP
ON / OFF / ENABLE
MONITOR AREA
ON / OFF
AREA SEL
1~4
TOP
000~244 (NTSC) / 000~288(PAL)
BOTTOM
000~244 (NTSC) / 000~288(PAL)
LEFT
600TVL
:
000~378 (NTSC)
、
000~370 (PAL)
700TVL
:
000~474 (NTSC)
、
000~468 (PAL)
RIGHT
600TVL
:
000~378 (NTSC)
、
000~370 (PAL)
700TVL
:
000~474 (NTSC)
、
000~468 (PAL)
DETECT SENSE: Set the motion detection sensitivity.
BLOCK DISP:
Control the ON/ OFF status of the motion detection block display.
MONITOR AREA: Set whether to use the monitoring frames.
AREA SEL:
Select the monitoring frame for setup.
TOP:
Set the selected top side of the monitoring frame.
BOTTOM:
Set the selected bottom side of the monitoring frame.
LEFT:
Set the selected left side of the monitoring frame.
RIGHT:
Set the selected right side of the monitoring frame.