36
3.8.4.1
Fire Alarm Setting
There are two fire alarm input modes: Normally Opened and Normally Closed. Normally
Opened means the circuit disconnects in the normal condition (i.e. without input) and
connects with activated inputs. Normally Closed is the opposite: the circuit connects in the
normal condition (i.e. without input) and disconnects with activated inputs.
Scroll to the preset input mode, press “5” to select. After finishing the setup, press “#” to
save the current setting and enter the door and fire alarm linkage setup interface. In case of
a fire alarm, the door may have two actions: open and close. Press “#” to toggle between
open and close. The system displays the current door action when a fire alarm sounds.
Press “*” to exit, and the setting is finalized upon exit.
3.8.4.2
Other Alarm Setting
If the set alarm is another type, the general Alarm Setting interface will show up. The
general Alarm Setting has three steps: First, set input mode; then set protection setup delay
time; and finally set the alarm time.
Input Mode:
*NC
NO
Output Mode:
* Latch
Input Mode:
*NO
NC
Output Mode:
* Latch
AlarmIN Type:1
*Other
Fire
C a n c e l
N e x t
Door Action on
Alarming
:
Close
[
#
]
to toggle
Door Action on
Alarming
:
Open
[
#
]
to toggle
Input Mode
:
*NO
NC
Alarm Port
:
1
N
AlarmIN Type
:
0
Others
*Fire
C a n c e l
N e x t