Installation Guide
Installation Guide
Install the unit on a hard and level surface
or the unit could produce undesired noises.
The unit should be at least 2” away from the
wall and the casters must be installed for
ventilation and proper operation
of the condensate evaporative system.
For the side mount units, a 7” space
should also be
afforded to the
left side of the
unit.
Indoor Use Only
Outdoor use may cause a decrease
in performance and
significant damage
to the unit.
Dusty and High Humidity Areas
Dusty environments will cause the
condenser coil to prematurely clog which
will require it to be cleaned more often.
High humid environments could cause the
unit to rust.
Do not build an enclosure or cabinet
around the unit.
Restricting the airflow around the unit’s
condenser area will cause the compressor to
work harder, which can result in compressor
failure and the unit
not being able to
maintain the desired
temperature.
Select a location away from other heat
and moisture generating equipment
such as stoves, ovens, dish washers, etc.
High ambient temperatures cause the
compressor to work harder, which can result
in compressor failure and the unit not being
able to maintain
the desired
temperature.
REFRIGERATION
Keep the unit upright at all times during
delivery. Tilting the unit during delivery
will cause harm to the refrigeration system.