INSTALLATION OF THE EVERDURE RBES67 & RBES97 RANGE HOODS DIRECTLY TO A WALL 

 
Ensure that the wall is structurally sound, and is capable of carrying the weight of the range hood. 

The range hood can be placed at a minimum of 600mm away from an electric cooktop, or 650mm 
minimum from a gas cooktop. The unit is held to a wall via 3 brackets (supplied with the unit): 

1)

 

Hook Bracket. 2)  Centre Bracket (flat). 3)  Top Bracket (U-shaped). 

Place the hood main unit (no u-shaped section) against the wall at the correct position and mark off the top 

edge of the unit.  Remove the unit and measure up 22mm to get the top level for the hook bracket.  Place the 
hook bracket (hooks up) under the mark and mark in the 3 screw holes.  Remove the bracket and drill three 
(3) Ø8mm holes 100mm apart.  Insert plastic plugs into the holes and fix the hook bracket onto the wall (see 
figure 1) with three (3) 40mm screws.  Place the hood main unit onto the hooks.  

If the position is correct, mark out the positions for the safety screw holes (through the back of the unit), and 
remove the hood body.  Drill two (2) Ø8mm holes and fit in two (2) plastic plugs. 
Screw the one way valve in position at the top of the body (4 x 8mm bolts) & fit the exhaust tube to the one 
way valve (see figures 2 & 3).   
Fit the u-shaped sections together & screw the centre bracket onto the back of the outer u-shaped section 

using the supplied 8mm screws (this helps keep the width at the back even with the front) (see figure 4).  
Place the u-shaped section onto the main unit and fix in place with two (2) 8mm screws (see figure 5).   
Hook the main unit with the u-shaped sections back onto the wall.  Mark the positions of the 2 holes needed 
to fix the centre bracket to the wall & remove the assembly.  Drill two (2) Ø8mm holes and fit in two (2) 

plastic plugs.  Place the assembly back on the hooks.  Fix the centre bracket to the wall with two (2) 40mm 
screws and fix the body to the wall with the 30mm screws (through the back of the main unit).  Run the loose 
end of the exhaust tube outside. 
Calculate the final height of the u-shaped section and pull out the inside u-shaped section to a suitable 

height (see figure 5) to check.  Mark the 2 sides near the top and push the inner section out of the way.  
Place the top bracket (slots to the bottom) centred between the 2 marks, mark the 2 screw holes. Remove the 
bracket and drill two (2) Ø8mm holes at the marks.  Insert plastic plugs into the holes and fix the hook 
bracket onto the wall (slightly loose) using 40mm screws.   
Pull up the inside u-section to allocate the top bracket correctly, and tighten the screws holding the bracket.  

Pull the u-section over the bracket completely and fix into place with 2 screws at the sides (see figure 7). 
Note: The top edge of the u-shaped bracket matches the top edge of the u-shaped section – adjust according 
to your own needs. 
 
For timber framed houses, special care should be taken that all brackets are attached to areas that will 

support the weight of the range hood. 
NOTE: Remove all protective plastic coatings from the stainless steel surfaces before use. 
 
 

 
 
 
 

 
 
 
       Figure 1                            Figure 2                               Figure 3                            Figure 4 
 

 
 

 
 

 
 
 

            Figure 5                              Figure 6                                          Figure 7 

Summary of Contents for RBES67

Page 1: ...DESIGNED TO PERFECTION INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR EVERDURE RANGE HOOD Models Included RBES67 RBES97...

Page 2: ...tallation 4 Installation Instructions 4 6 Operating Instructions 6 Replacing The Bulbs 6 Cleaning 7 Troubleshooting 7 It is important that you retain these instructions proof of purchase as well as ot...

Page 3: ...ance from the outlet 13 It is recommended to operate the range hood prior to cooking 14 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to co...

Page 4: ...nce to the local electrical authority and codes This range hood must be earthed at all times for the operators safety The switched power outlet for the range hood should be positioned to enable the us...

Page 5: ...e 4 Place the u shaped section onto the main unit and fix in place with two 2 8mm screws see figure 5 Hook the main unit with the u shaped sections back onto the wall Mark the positions of the 2 holes...

Page 6: ...motor will run at a low speed Push the medium button indicated by a fan with 4 blades and the motor will run at a medium speed Push the high button indicated by a fan with 5 blades and the motor will...

Page 7: ...f a fire hazard due to grease and fat build up TROUBLESHOOTING Fault Possible Cause Solution Light on but motor does not work Fan switch turned off Select a fan switch position Fan switch failed Conta...

Page 8: ...ice and Assembly Enquiries 1300 766 066 A division of Shriro Australia Pty Ltd 104 Vanessa St Kingsgrove NSW 2208 In Australia 1300 355 541 In New Zealand 09 414 5755 www everdure com IM Ref RBES67 19...

Reviews: