background image

 

 

2                      For Professional Technical Support call 1-844-241-5521 

 

Table of Contents

 

 

 
Table of Contents .......................................................... 2

 

Performance .................................................................. 2

 

Safety Information ......................................................... 2

 

Warranty ......................................................................... 3

 

Pre-Installation .............................................................. 4 

 

 
Installation ..................................................................... 6

 

Operation ....................................................................... 7

 

Care and Cleaning ........................................................ 8

 

Troubleshooting ............................................................ 9

 

 

Performance

 

 

 

 

SKU 

HP 

GPH of Water @ Total Feet Of Lift 

Max. Lift 

0 ft. 

5 ft. 

10 ft. 

15 ft. 

20 ft. 

25 ft. 

1000026686 

1/3 

4000 

3700 

3300 

2800 

1860 

25 ft. 

1000026682 

1/2 

4200 

4000 

3600 

3200 

2400 

1200 

29 ft. 

1000026675 

3/4 

5150 

4800 

4320 

3660 

2580 

25 ft. 

1000026662 

5500 

5160 

4680 

4200 

3480 

2340 

30 ft. 

 
 

Safety Information

 

 

 

 

DANGER: 

Do not pump flammable or explosive liquids 

such as oil, gasoline, kerosene, ethanol, etc. Do not use in 
the presence of flammable or explosive vapors. Using this 

pump with or near flammable liquids can cause an 
explosion or fire, resulting in property damage, serious 

personal injury, and/or death.

 

 

 

 

DANGER: 

ALWAYS disconnect the power to the pump 

before servicing.

 

 

 

 

DANGER: 

Do not touch the motor housing during 

operation. The motor is designed to operate at high 

temperatures. Do not disassemble the motor housing.

 

 

 

 

DANGER: 

Do not handle the pump or pump motor with 

wet hands or when standing on a wet or damp surface, or 

in water before disconnecting the power.

 

 

 

 

WARNING: 

Release all pressure and drain all water 

from the system before servicing any component.

 

 

 

 

WARNING: 

Secure the discharge line before starting the 

pump. An unsecured discharge line will whip, possibly 

causing personal injury, and/or property damage.

 

 

 

 

WARNING: 

Extension cords may not deliver sufficient 

voltage to the pump motor. Extension cords present a life 

threatening safety hazard if the insulation becomes 
damaged or the connection ends fall into water. If 

receptacle is not within reach of the pump’s power cord, 
contact a qualified licensed electrician to install a new 

receptacle.

 

 

 

WARNING: 

Wear safety goggles at all times when 

working with pumps.

 

 

 

 

WARNING: 

This unit is designed only for use on 115 

volts (single phase),60 Hz, and is equipped with an 
approved 3-conductor cord and 3-prong grounded plug. Do 
not remove the ground pin under any circumstances. The 

3-prong plug must be directly inserted into a properly 
installed and grounded 3-prong, grounding-type 

receptacle. Do not use this pump with a 2-prong wall 
outlet. Replace the 2-prong outlet with a properly 

grounded 3-prong receptacle (a GFCI outlet) installed in 
accordance with the National Electrical Code and local 

codes and ordinances. All wiring should be performed by a 
qualified electrician.

 

 

 

 

WARNING: 

Protect the electrical cord from sharp 

objects, hot surfaces, oil, and chemicals. Avoid kinking the 
cord. Do not use damaged or worn cords.

 

 

 

 

WARNING: 

Failure to comply with the instruction and 

designed operation of this unit may void the warranty. 

ATTEMPTING TO USE ADAMAGED PUMP can result in 
property damage, serious personal injury, and/or death.

 

 

 

 

WARNING: 

Ensure that the electrical circuit to the pump 

is protected by a15 Amp fuse or circuit breaker.

 

 

 

 

CAUTION: 

Do not lift the pump by the power cord.

 

 

 

Summary of Contents for 1000026662

Page 1: ...of products available for your home improvement needs Thank you for choosing Everbilt SKU 1000026686 1000026682 1000026675 1000026662 Model SP03302VD SP05002VD PSSP07501VD PSSP10001VD USE AND CARE GUIDE SUBMERSIBLE SUMP PUMP Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM Rev 05 20 17 SKU 10000...

Page 2: ...ine will whip possibly causing personal injury and or property damage WARNING Extension cords may not deliver sufficient voltage to the pump motor Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water If receptacle is not within reach of the pump s power cord contact a qualified licensed electrician to install a new recept...

Page 3: ...e If within five years 1000026675 1000026662 and three years 1000026686 1000026682 this product is found upon examination by the manufacturer to be defective in materials or workmanship the manufacturer s only obligation and your exclusive remedy is the repair or replacement of the product at the manufacturer s discretion provided that the product has not been damaged through misuse abuse accident...

Page 4: ...salt water or brine Use with waterfalls fountains salt water or brine will void warranty Do not use where water recirculates Not designed for use as a swimming pool drainer TOOLS REQUIRED MATERIALS REQUIRED NOT INCLUDED NOTE Parts shown below not to scale 1 1 4 in or 1 1 2 in check valve 1 1 4 in or 1 1 2 in 90 elbow 1 1 4 in or 1 1 2 in discharge pipe adapter Phillips Screwdriver Flathead Screwdr...

Page 5: ...ith adapter Sump basin Minimum 10 in 254mm diameter 15 in 381mm depth Switch on off 1000026686 On 7 2 in 183mm Off 2 8 in 71 1mm Switch on off 1000026682 On 7 6 in 193mm Off 3 2 in 81 3mm Switch on off 1000026675 1000026662 On 8 8 in 223mm Off 4 4 in 112mm NOTE Do not reduce size of discharge pipe or hose below 1 1 4 in diameter If discharge is too small pump will overheat and fail prematurely Thi...

Page 6: ...d make sure the pump is secured in the sump to prevent movement Failure to secure the pump may allow pump movement switch interference and prevent the pump from starting or stopping 5 To reduce motor noise and vibrations a short length of rubber hose 1 7 8 in 47 6mm I D e g radiator hose can be connected into the discharge line near the pump using suitable clamps 6 Install an in line check valve o...

Page 7: ...or pump motor with wet hands or when standing on a wet or damp surface or in water 1 The shaft seal depends on water for lubrication Do not operate the pump unless it is submerged in water as the seal may be damaged if allowed to run dry 2 The motor is equipped with an automatic reset thermal protector If temperature in the motor should rise unduly the switch will cut off all power before damage c...

Page 8: ...FCI outlet Do not disassemble the motor housing This motor has NO repairable internal parts and disassembly may cause leakage or dangerous electrical wiring issues Do not lift up the pump by the power cord To clean a pump clogged with debris Unplug the pump from electrical power Unscrew the stainless screws 5 and remove the volute 4 If necessary use a flathead screwdriver to hold the shaft 1 then ...

Page 9: ... little or no water 1 The screen is blocked 2 Debris is caught in the impeller or discharge 3 The impeller is broken 1 Clean the screen 2 Remove the debris 3 Replace the impeller The pump starts and stops too often 1 There is a backflow of water from the piping or the check valve is leaking 2 The float switch is stuck 3 The float switch failed 1 Install a check valve or replace the check valve 2 C...

Page 10: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 241 5521 HOMEDEPOT COM ...

Reviews: