8 For Professional Technical Support call 1-844-241-5521
Care and Cleaning
CAUTION:
Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and
allow time for it to cool after periods of extended use.
Do
Do Not
When the power is disconnected, inspect the pump suction
screen and remove all debris, then plug the pump back into
the grounded (GFCI) outlet.
Do not disassemble the motor housing. This motor has NO
repairable internal parts, and disassembly may cause
leakage or dangerous electrical wiring issues.
Do not lift up the pump by the power cord.
To clean a pump clogged with debris
:
Unplug the pump from electrical power.
Unscrew the stainless screws (5), and remove the volute (4).
If necessary use a flathead screwdriver to hold the shaft (1), then turn the impeller (2) counterclockwise to release the impeller (2).
Remove debris from around the shaft (1) and the impeller (2).
Reassemble the pump.