Remove appropriate mounting knockouts on top, bottom or sides of backbox. Attach Bar Hangers to
backbox using Bolts and Hanger Clamps supplied.
Using hardware supplied by others, attach to wood studs or joists with screws or nails, attach to metal
studs with sheet metal screws with a minimum pullout rating of 25 lbs. Hanger bars will rest directly on
drop ceiling T-Bars and can be secured by screws or wire (supplied by others).
UNIT IS APPROVED FOR
TYPE IC INSTALLATION.
Align backbox so lamphead opening is flush, or slightly behind inner surface of ceiling or wall.
ROUGH-IN CEILING AND WALL MOUNT
SUPPORTING MEMBERS MUST BE ABLE TO SUPPORT A LOAD OF AT LEAST 25 LBS.
WALL MOUNT
16"
C/L TO C/L
Attach
backbox
directly
to stud
BAR HANGERS
DO NOT INSTALL SPLICE BOX COVER INTO BACKBOX
UNTIL WIRING IS COMPLETE
BACKBOX INSTALLATION
Page 2
(4) BAR HANGER
Bar Hangers
telescope when
assembled
adjust from
14-1/2" to 24"
HARDWARE KIT
(4)
(3)
(2) HANGER CLAMP
Wood joist or
stud mounting
Ceiling tile thickness
1" max.
Up to 2" high T-Bars