EVENES CIRCULATING PUMP
EV-ZUP 15
25
EVENES CIRCULATING PUMP
EV-ZUP 15
24
EN
4.1 Technical data EV-ZUP 15
4 | SPECIFICATIONS RELATED TO THE PRODUCTS
The service water pump is used for circulation in single and two-family
houses with a pipe length of up to 50 m.
3 | INTENDED USE
• 3 Constant characteristic curves
• Display of the selected characteristic curve
• Motor short-circuit proof
• Max. 10 bar operating pressure
• Max. 65° C water temperature
• Output 2.5-8 Watt
• Stainless steel encased Rotor
• Technopolymer impeller
H
1,00
0,75
0,50
0,25
0
(m)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7 Q m
3
/h
stage 1
stage 2
stage 3
5.1 Manual
After connecting of the pump with the power supply LED lights on the control panel are showing
the selected level.
For level 1 – the first LED lights up, for level 2 – the first and the second LED are glowing,
for level 3 – all three LED’s are illuminating.
By pressing of the button
all levels will be switched continuously. The pump can be optimally
adapted to the system By selecting of the most appropriate curve.
Three flashing LED lights signals an error.
LED 3
LED 1
LED 2
Taste
5 | PUMP SETTINGS AND OUTPUT
5.2 Startup
The system must be thoroughly flushed before the pump is started up to prevent contaminants
or foreign bodies from remaining in the system. The system must then be thoroughly vented.
The pump‘s union nut must be slightly loosened for this to allow the air to escape from the
pump. The supply line is then carefully opened until water leaks out on the pump. Please ensure
that the electrical connection is protected against water and moisture. It is recommended that
the pump be deactivated for this.
A suitable tool is then used to tighten the union nut and the pump can be started up. Audible
flow noises indicate that air is present in the pipe system. This process may need to be
repeated and in any case, the pump must be prevented from running dry for prolonged
periods.