c9

0

120

s

10

c11

0

100

%

25

c12

0

999

min

60

PARAM. MIN

MAX

U.M.

DEF.

F2

0

1

- - - -

1

F3

1

120

s

15

F4

1

60

min

3

PARAM. MIN

MAX

U.M.

DEF.

A1

0

999

°

C/

°

F (1) 0

A2

0

240

min

0

A3

0

2

- - - -

0

PARAM. MIN

MAX

U.M.

DEF.

i1

0

1

- - - -

0

i5

0

4

- - - -

0

i6

0

1

- - - -

0

i7

0

120

min

0

i8

0

2

- - - -

0

PARAM. MIN

MAX

U.M.

DEF.

LA

1

247

- - - -

247

Lb

0

3

- - - -

2

LP

0

2

- - - -

2

(1)

the unit of measurement depends on parameter P2

(2)

the parameter P0 is not available in the models for Pt 100 2-wire probes

(3)

appropriately set the parameters relative to the regulators after modification of parameter P2

(4)

if parameter P4 is set at 0, the instrument will function as if the parameter P5 is set at 0

(5)

if parameter P6 is set at values different to 6, these will have no effect in the following conditions:
- during the pre-heating phase (the lower part of the display will show “

PrEH

”)

- on the conclusion of the pre-heating phase, in stand-by for start-up of the cooking phase (the lower part of the display shows flashing “

rdY

”)

- during the pre-heating phase (the lower part of the display will show flashing “

PAUS

”)

- on conclusion of the cooking phase (the lower part of the display will show flashing “

End

”)

- on conclusion of the program (the lower part of the display will show flashing “

EndP

”)

- during the core cooking phase (if P6 = 2) and during the continuous cooking phase (the lower part of the display will show “

- - - -

”)

(6)

if parameter P4 is set at 0, the instrument will function as if the parameter P6 is set at 0

(7)

if the power supply cut-off is shorter than the time set with parameter r13, the count will also continue hen the instrument is no longer powered. Parameter r13 has no effect during the core cooking phase
and during the continuous cooking phase

(8)

ds = tenths of second

(9)

the parameter differential is 10 

°

C/18 

°

F

(10)

pressing the 

 key causes the associated effect

(11)

if parameter i5 is set at 4 and parameter i8 is set at 1, the “

id

” code cannot be displayed, the buzzer, the acoustic output and the buzzer output will not be switched on.

time that passes between the switch-on of the buzzer and the acoustic output and the conclusion of a timed cooking phase, a steam cooking phase and a grill cooking phase;
see also c4
duration of grill switch-on (percentage of c1)
time that must pass (from programmed switch-on of the instrument) without having to operate on the keys (or with the multifunction input) so that the instrument passes to the
programmed switch-on status again
0 = no function
FAN
enabling of reversal of the direction of the fan movement
1 = YES
duration of fan switch-off (time between switch-off of the fan output and switch-on of the reversal of the direction of the fan movement; only if F2 = 1)
duration of every fan movement direction (duration of switch-on of the fan output and the inversion output of the direction of movement of the fan; only if F2 = 1)
TEMPERATURE ALARMS
chamber temperature over which the chamber temperature alarm is activated, see also A3 (9)
chamber temperature alarm delay
type of chamber temperature alarm
0 = no alarm
1 = absolute (i.e. A1)
2 = relative to the work set-point of the phase in progress (i.e. “work set-point of the phase in pr A1”)
DIGITAL INPUTS:
on/stand-by input polarity
0 = live active input
1 = non-live active input
effect caused by the activation of the multifunction input
0 = no effect
1 = SWITCH-ON/OFF OF THE CHAMBER LIGHT - the activation of the input will cause the chamber light to switch-on and the successive activation causes its switch-off
2 = BUZZER SWITCH-OFF, ACOUSTIC OUTPUT AND BUZZER OUTPUT - The activation of the input will cause the buzzer, the acoustic output and the buzzer output to switch-off

(activate the input again to switch these utilities off)

3 = STEAM INJECTION - in this case:

• if t0 = 0,the activation of the input will cause the injection of the steam for the time established with parameter t2 or for the entire duration of the activation of the input (the

parameter t1 establishes the minimum time that will pass between the two successive injections) (10)

• if t0 = 1, the activation of the input will enable the automatic injection of the steam (in cyclical mode; the parameter t2 establishes the duration of the injector switch-on and

parameter t1 establishes the duration of switch-off) until the input is activated again (10)

4 = DOOR MICRO SWITCH - the activation of the input will cause the switch-off of the output for the regulation of the temperature, of the grill, of the airhole, of the steam injector

and the fan, the display of the flashing “

id

” code, the switch-on of the buzzer, the acoustic output and the buzzer output and the suspension of the count of the duration

of the phase until the input is deactivated; see also i7 and i8 (11)

type of contact of the multifunction input
0 = NO (input active with closed contact)
1 = NC (input active with open contact)
multifunction input alarm signal delay (only if i5 = 4)
event that causes the passage from the conclusion of the pre-heating phase to the cooking phase following the pre-heating phase
0 = pressing the 

 key for 1 s

1 = pressing the 

 key for 1 s and activation and successive deactivation of the multifunction input (only if i5 = 4)

2 = activation and successive deactivation of the multifunction input (only if i5 = 4)
SERIAL NETWORK (MODBUS)
instrument address
baud rate
0 = 2.400 baud
1 = 4.800 baud
2 = 9.600 baud
3 = 19.200 baud
parity
0 = none (no parity)
1 = odd
2 = even

Summary of Contents for EV9376

Page 1: ...ng conditions before the conclusion of the steam cooking phase the time established with parameter c5 for the time established with parameter c6 in manual mode for the time established with parameter...

Page 2: ...ic output will be on for 3 s During the phase the upper part of the display shows the established quantity with parameter P5 for predefined setting of the chamber temperature the lower part of the dis...

Page 3: ...y StEA When the count of the duration of the phase is completed the phase is concluded Before the conclusion of the phase of the time established with parameter c9 the buzzer and the acoustic output a...

Page 4: ...tion deactivation of grill switch on in cyclical mode only if parameter r17 is set at 0 make sure a grill cooking phase is in progress and that no procedure is in progress press for 4 s the LED will s...

Page 5: ...o Monday the time in the 24 hour format hours minutes To modify the day press or within 15 s press the left part of the indication relative to the ignition time will flash To modify the hour press or...

Page 6: ...rt of the display will be showing another quantity clock real time LED if it is on the quantity shown on the lower part of the display will be the real time if it flashes setting of the day and real t...

Page 7: ...ng phase core temperature during the core cooking phase during the continuous cooking phase MAIN REGULATOR work set point differential of the pre heating phase and of the work set point of any cooking...

Page 8: ...trument without having to operate on the keys or with the multifunction input so that the instrument passes to the programmed switch on status again 0 no function FAN enabling of reversal of the direc...

Reviews: