10
3 Flash: COMPRESSOR START ERROR
Cause:
• Stopping and starting too quickly (not giving the system time to equalize) .
• Electronic box issue .
• Faulty compressor .
• Disconnect power for ten minutes, then re-start, if problem persists, contact Evakool .
4 Flash: MINIMUM MOTOR SPEED ERROR
Cause:
• If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm .
• Very high ambient temperatures (move to a cooler area) .
• Blocked or dirty condenser (clean and re-test) .
• Fan not working (contact Evakool) .
5 Flash: OVER TEMPERATURE ERROR
Cause:
• Ambient temperature too high (move to a cooler area) .
• Blocked or dirty condenser (clean and re-test) .
• Fan not working (contact Evakool) .