Summary of Contents for MAXI TRAC MT-45

Page 1: ...POWERED BY INSTRUCTION MANUAL FOR MODELS MT 45 MT 60 MT075 DX...

Page 2: ......

Page 3: ...copy at Evakool com au or contact Evakool on 07 5492 5495 3 Contents 1 Safety Instructions 4 2 Operating Instructions 5 2a Initial Start Up 5 2b Control Panel 6 3 Energy Saving Tips 7 4 Defrosting Cl...

Page 4: ...Not to be operated by children Do not place or store any electrical devices inside the unit as they may be damaged Disconnect from power supply and remove lead before defrosting cleaning and maintena...

Page 5: ...nto the wall socket Press and hold the for 3 seconds The display will light up showing the temperature inside the unit You will hear the compressor start first then the cooling fan will start Your fri...

Page 6: ...own 3 Fault light the unit has a built in fault finding system refer to trouble shooting guide 4 Turbo light see speed selection 2 Above 5 LED Display Displays the temperature inside the fridge In the...

Page 7: ...and cleaning 4 4 Defrosting Cleaning WARNING Always turn unit off and remove power cord before cleaning Do s Turn off and allow unit to defrost Wipe out water before restarting Clean inside regularly...

Page 8: ...tween Celsius and Fahrenheit Mode Change compressor speeds see 2b control panel speed selection Press BACK button to return to the home screen 4 This is the fridge turned off 5 This is the fridge turn...

Page 9: ...own built in fault finding system depending on how many fashes per 5 flashes Led display shows Error codes ER1 ER2 This is a thermistor issue contact Evakool 07 54927777 Refers to fault light error 1...

Page 10: ...MINIMUM MOTOR SPEED ERROR Cause If the refrigeration system is too heavily loaded the motor cannot maintain minimum speed at approximately 1 850 rpm Very high ambient temperatures move to a cooler are...

Page 11: ...8 A Hr Fridge Freezer 2 5 A Hr Turbo 16 C 2 0 to 2 5 A Hr Turbo 16 C 2 0 to 2 5 A Hr Voltage DC 12 24 AC 100 240V 50 60hz Insulation Cabinet 45 to 58mm Lid 45mm C pentane totally CFC Free Refrigerant...

Page 12: ...ottling Device Capillary Power Supply V DC 12 24 Test Conditions Evaporating Temp 23 C Suction Temp 32 2 C Condensing Temp 54 4 C Sub Cooling Temp 32 2 C Ambient Temp 32 2 C Test Voltage 12VDC for 24V...

Page 13: ...13 7a Dimensions Parts MT45...

Page 14: ...14 MT60...

Page 15: ...15 MT75...

Page 16: ...2 B RC65 Cabinet 15 RC45 65 75D 010 Power Switch 5A RC45 65 003 A RC45 Basket 16 RC45 65 006 Compressor 5B RC45 65 003 B RC65 Basket 17 RC45 65 75D 011 Compressor Base Board 6 RC45 65 75D 003 Door Hin...

Page 17: ...5 65 75D 004 LED Light 17 RC45 65 75D 012 Condenser 6 RC75D 003 Basket 1 18 RC45 65 75D 013 Fan 7 RC75D 004 Basket 2 19 RC45 65 75D 014 Capillary 8 RC45 65 75D 003 Door Hinge 20 RC75D 007 Compressor 9...

Page 18: ...built in Turbo mode for faster cooling Self diagnostic fault system Smooth interior walls hygienic and easy to clean Downloadable APP Wi Fi to monitor and control the fridge Handles can be used as ti...

Page 19: ......