background image

06

“           ” (Short press once to enter Basic Setting Mode)

Setting procedure : 

Max. pressure 

 Min. start pressure 

 

Time-Delay

Item Parameters Display

Code

Default

Unit

Data

Range

P-max kg/cm² 0.01~

10.00

Description

Max. pressure 

setting

(high pressure)

a.Select to modify Max. Pressure, press the 

left or right button to adjust the value, after 

finishing the setting, press the SET button 

once and go to Min. start pressure 

1

0~60

kg/cm²

sec

-

-

P-min

Delay

loAd

Min. start 

pressure setting 

(low pressure)

Time-Delay 

setting when

reaching the 

Max. Pressure 

Load for 3 

seconds to store  

 setting value 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    
c.Choose not to modify the pressure, press

 the SET button, and go to next parameter 

setting.

a.Select to modify Min. start pressure , press 

the left or right button to adjust the value,

after finishing the setting, press the SET 

button once and go to Time-Delay setting .

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    

c. Choose not to modify the pressure, press 

the SET button, and go to next parameter 

setting.

a.Select to modify the Time-delay setting 

when reaching the Max. Pressure, press 

the left or right button to adjust the value, 

after finishing the setting, press the SET 

button and go to " loAd " display. 

b.Stay on this screen for 30 seconds, the

   display screen will automatically return to 

   the current pressure conditions and the

   preset data value will not be stored.    

c.Choose not to modify the delay time, press 

the SET button, and LCD display " loAd "

The above setting value is stored and after 

3 seconds will automatically return  to the 

current pressure value.

2

3

4

setting.

0.01~

10.00

5.The status of LED lights 

6.Parameter display and settings

Item

Light

Message indication 

Control loop off from the system

Non

Green
Orange 

Red 

Pump status

Control loop commands the system 

pump to start running

Control loop is loaded into the system

Warning message to shut down the

system temporarily

Pump off

Pump on

Pump standby

Pump auto stop and display   

the fault message (Dry running

1

2
3

4

Item Parameter Display

Code

Default

Unit

P-max kg/cm²

kg/cm²

kg/cm²

P-min

P-Dry

Description

Pressure of 

water shortage 

setting display 

(Dry running)

Min. Pressure

setting display

Max. Pressure

setting display

» Press once: To see the Max. pressure setting value.

» Or stay on this screen for 5 seconds it will automatically 

 return to the current pressure status display.

» Press again: To see the Min. pressure setting value. 

» Or stay on this screen for 5 seconds it will automatically 

return to the current pressure status display.

» Press again: To see the pressure of  water shortage  

setting value.

» Or stay on this screen for 5 seconds it will automatically 

return to the current pressure status display.

1

2

3

“            ” (Pressure value display)

 or Over pressure)

Item Parameter Pump action

Description

Stop (OFF)

Restart (ON)

Pump off

Non

Pump on

Orange  Press once to restart the pump running.

Hold down for 3 seconds to stop the pump 

1
2

“            ” (Restart or stop the pump running)

running.

Light

Lock/Unlock

Setting function

kg/cm²

Long press for 6 seconds (Lock/Unlock the SET button)

Summary of Contents for DPC-10

Page 1: ... lation and Operation Manual EVAK PUMP TECHNOLOGY CORP No 551 Zhongshan Rd Qingshui Dist Taichung City 436 Taiwan TEL 886 4 26233556 Fax 886 4 26235559 11 Warning Assemble tool Do not poke the port Do not pull the cable Wire conductors must not be exposed to avoid any shortage from the conductor end WARNING ...

Page 2: ...lay Technical Data Button Pressure Unit Relay Capacity 1HP in 110V or 2HP in 230V The digital pressure controller can control pump with higher output through a contactor with control circuit voltage of 110Vac or 230Vac in the other hand the supply voltage to DPC is 110Vac or 230Vac 50 60hz please refer to the wiring diagram for requirement Dry Running Digital Pressure Controller DPC 10 Over Pressu...

Page 3: ...the voltage is over 250V please add transformer by yourself DPC 10 Controller Gray Brown Blue Black AC 230V M1 Coil DPC 10 Controller Gray Brown Blue Black 1 phase PUMP WARNING WARNING WARNING Any connection to the contactor please add a R C capacitor spark eliminator to reduce the possible electromagnetic interference WARNING Beware of any connection to the contactor Please add a R C capacitor sp...

Page 4: ...o the current pressure conditions and the preset data value will not be stored c Choose not to modify the delay time press the SET button and LCD display loAd The above setting value is stored and after 3 seconds will automatically return to the current pressure value 2 3 4 setting 0 01 10 00 5 The status of LED lights 6 Parameter display and settings Item Light Message indication Control loop off...

Page 5: ...ing 2 3 0 600 sec hour Auto Reset Auto Time setting of automatic re start running after warning shutdown Dry running or Over pressure α value Auto shutdown setting after continuous running a Select to modify automatic re start time press the left or right button to adjust the value after finishing the setting press the SET button and go to next parameter setting The time of automatic re start auto...

Page 6: ...e right button and adjust the parameter value from dF n to dF y After finishing the setting press the SET button then all the advanced value settings are returned to default value LCD screen will display for 3 seconds and return to the current pressure conditions b Stay on this screen for 30 seconds the display screen will automatically return to the current pressure conditions and the preset data...

Page 7: ...ss for 6 seconds to Lock Unlock the SET button 1 Max pressure setting high pressure Show code P max b Press once to enter basic setting Press to adjust the value upward Press to adjust the value downward 2 Min Start pressure setting low pressure Show code P min Press once Press to adjust the value upward Press to adjust the value downward Press once ...

Page 8: ...stored Show code loAd c Press for 3 seconds to enter advanced setting Press to adjust the value upward Press to adjust the value downward Press once 3 seconds later 5 After finishing above setting 3 seconds later will return to the current pressure status display automatically Press to set up unit Cycle of working pressure unit kg cm psi bar kg cm Press once ...

Page 9: ...tdown Dry running or Over pressure α value Show code Auto reset Press to adjust the value upward Press to adjust the value downward Press once Press to adjust the value upward Press to adjust the value downward Press once St 0 Pressure controller keeps running and will not automatically shut down St 5 St 1 5 Pressure controller will auto shut down after continuously running 0 5 or 1 5 hours and wi...

Page 10: ... 6 Restore to default value setting or not To restore default value settings show code dF y Press to adjust the value to dF y Press once and restore to default value Show code 7 After finishing above settings LCD screen display loAd or 3 seconds later above setting value is stored and it will automatically return to the current pressure value Not to restore default value settings show code dF n Pr...

Reviews: