04. ELECTRONICS WITH DUEPI 3 BUTTON LED DISPLAY
(Pellet Stove)
04.1 CONSOLE
Description of Console:
1) Button 1 opens the work programme settings. During setting, press it to move to the next menu item or increase the displayed value.
2) Button 2 opens the work temperature settings. During setting, press it to go back to the previous menu item or decrease the displayed value.
3) TIMER LED: It is on when the programmer timer setting is enabled.
4) TEMP OK LED: When illuminated, indicates that the room temperature has been reached. The stove then continues the heating in ECO mode.
5) DISPLAY LED: Indicates the stove working status and the settings menu.
6) AUGER TUBE LED: It is on when the Auger tube is working.
7) IGN LED: It is on when the ignition plug is on.
8) ON/OFF: It is the stove switching on/off button. Keep it down for a few seconds to switch the stove on. Press it also to clear the alarm displayed.
During temperature setting, press it to enter the technical menu.
9) LED ON: It is on when the stove is switching on or heating. It flashes when the stove is in the cooling phase or error.
10) IR: Optional IR remote control sensor.
11) AL: It is on or flashes if the pressure switch or the safety thermostat were triggered.
04.2 USER FUNCTIONS
Standard operation of a control board correctly installed on an forced air stove is described below with reference to the functions available to users.
The board automatically controls the stove working parameters. Users can manually switch the stove on or off and use the advanced functions, such as the weekly
programmer or the timer.
First Start-up
Upon switching on the board, the display shows the resident software version and then the stove status (OFF in case of first ignition).
Temperature Settings
To open the temperature settings, press button
2
and then
1
and
2
to change the temperature from a minimum of 7 to 40°C. If button
8
is pressed in the temperature
settings, the technical menu opens up.
Working Programme Settings
The working programme actually corresponds to the stove heat output. To open the settings, press button
1
and then
1
and
2
to change the programme from a
minimum of 1 to 5.
Press and hold button
1
down to visualise the measured flue gas temperature and then the flue gas motor speed in revolutions per minute, if the encoder is
connected.
Stove ignition
To ignite the stove, press button
8
for a few seconds. The stove will automatically continue the ignition and heating phase. Upon the first ignition and therefore
the first pellet loading, several ignition cycles need to be carried out in order for the pellets to enter the feeding system.
Stove switch off
To switch the stove off, simply press button
8
. After a system-controlled cooling phase, the stove is switched off.
System Error Reset
The stove signals any malfunctions detected through the relevant error code and message. Hold button
8
down for approx. 3 seconds until the error message
disappears from the LED display to clear any errors and then switch the stove back on.
Pellet Economy
If during the heating phase the room temperature exceeds the set value, LED
4
switches on and the stove limits its heat output to maintain the set temperature.
If the stove temperature further increases by the T value set in the system parameters, the stove enters the pellet economy mode, then the cooling phase. The
stove automatically resumes operation if room temperature reaches a value below the set value for at least 1 minute.
4