EVA Stampaggi KALI THELMA Instruction Manual Download Page 3

01. FLUE PIPE 

 

01.1 FLUE PIPE CHARACTERISTICS  

 

PELLET STOVE 8 KW (9) SPCT8 

Chimney flue draught 

12   Pa 

Fume temperature 

214  °C 

Maximum flue smoke flow 

6.1   g/s 

 

   

   

   

 

 

   

 

02. INSTALLATION WARNINGS  

 

 

 

  If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood cladding, etc.), 

the following minimum clearances 

must be complied with:  

 

STOVES and BOILERS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                       FLAMMABLE                            

NON

    FLAMMABLE                                                              

 

   

   

   

   

   

   

   

 

 

 

 

  

   

   

   

 

PELLET STOVE 8 KW (9) SPCT8 

 

PELLET STOVE 8 KW (9) SPCT8 

 

REAR WALL P = 

100  mm    REAR WALL P = 

100  mm   

SIDE WALL L =  

250  mm    SIDE WALL L =  

150  mm   

FLOOR F = 

-  mm    FLOOR F = 

-  mm   

FRONT R = 

1000  mm    FRONT R = 

1000  mm   

 

   

   

  

 

 

 

   

   

   

 

03. INSTALLATION 

 

03.1 TRADITIONAL PELLET STOVES

 

 

IMPORTANT: THE LENGTH OF THE SMOKE DUCT MUST BE A MAXIMUM OF 6 METRES OF 80 mm DIAMETER TUBE AND EACH 90° BEND OR (T) 

CONNECTION MUST CORRESPOND TO 1 METRE OF TUBE 

 

TO GUARANTEE THE CORRECT OPERATION AND YIELD OF ALL OUR PELLET ITEMS, BEFORE CARRYING OUT A CONNECTION TO THE FLUE PIPE 

INSTALL A T-CONNECTION AND AT LEAST 1 LINEAR METRE OF SMOKE DUCT CERTIFIED IN ACCORDANCE WITH EN1856-2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 