03. INSTALLING THE PRODUCT
18
03.6 INSTALLATION
Using coaxial tubes the air will be pre-warmed contributing to improved combustion and lower emissions into the atmosphere.
Follow the instructions before installing your stove.
Select the position where the stove is to be installed and:
Arrange the connection to the vent pipe for fume extraction.
Arrange the external air intake (combustion air).
Arrange the connection to the earthed mains.
The electrical system of the room where the stove is to be installed must be earthed, otherwise the control board may not
work properly.
Place the stove on the floor in a convenient position for the connection to the vent pipe and close to the combustion air
intake.
The appliance must be installed on a floor with an adequate loading-bearing capacity.
Should the existing floor not comply with the requirement above, proper measures must be taken (for instance, the
installation of a load distribution plate).
All the structures which can catch fire if exposed to excessive heat must be protected. Floors made from wood or
inflammable materials must be protected using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
This appliance is not suitable to be installed on a shared vent pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must
be positioned at the same height of the pipe located on the stove back. Exhaust fume pipes must be suitable for pellet
stoves and must therefore be made from coated steel or stainless steel, with a diameter of 8cm and fitted with adequate
gaskets.
Summary of Contents for HYDRO CURVED FRONT 20 KW
Page 3: ...2...
Page 9: ...01 PRODUCT SAFETY 8 01 3 EC CERTIFICATE OF CONFORMTY...
Page 22: ...03 INSTALLING THE PRODUCT 21 CONNECTION EXAMPLES SYSTEM DRAWINGS...
Page 23: ...22 03 INSTALLING THE PRODUCT...
Page 39: ...04 PRODUCT USE 38 Connections...
Page 44: ...43...