05. PRODUCT USE
05.1 ELECTRONICS WITH 6-BUTTON LED DISPLAY p. 42 F-1
(Pellet inserts – Canalized pellet stove)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
First connect the stove plug to the mains and load the pellet hopper. Be careful not to empty the entire bag at once. Perform this operation slowly.
DESCRIPTION OF PANEL
BUTTON (P1)
- Temperature increase:
When in (SET TEMP) mode, use this button to increase the thermostat value from a minimum of 6° C to a maximum of 41° C. The selected value appears on
the lower display, while the upper display shows the message SET. When modifying user and technician parameters, use this button to increase the parameter
value. The selected value appears on the lower display. When in working mode, use this button to visualise the fume temperature on the lower display.
BUTTON (P2)
- Temperature decrease:
When in (SET TEMP) mode, use this button to decrease the thermostat value from a maximum of 41° C to a minimum of 06° C. The selected value appears on
the lower display, while the upper display shows the message SET.
When modifying user and technician parameters, use this button to decrease the parameter value. The selected value appears on the lower display. When in
working mode, use this button to visualise the time on the lower display.
BUTTON (P3)
- Set/menu:
Use this button to access (SET TEMP) temperature setting and user and technician parameter menu. Press P3 button repeatedly to cycle through all the
parameters inside the menu. The upper display visualises the parameter label, while the lower display shows the relevant value.
BUTTON (P4)
- ON/OFF Release:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status (switched ON or OFF).
Should have any alarm blocked the stove, press this button to unlock it and subsequently switch it OFF.
When setting user/technician parameters, use this button to exit the menu at any setting step.
BUTTON (P5)
- Heat output decrease:
When in working mode (ON), use this button to decrease the heat output from 5, maximum value, to 1. The selected value appears on the upper display.
BUTTON (P6)
- Heat output increase:
When in working mode (ON), use this button to increase the heat output from 1, minimum value, to 5. The selected value appears on the upper display.
ECO – Temperature reached: When the required temperature is reached, the message ECO appears on the display. P5 and P6 buttons are disabled
automatically. Change the set temperature to enable P5 and P6 buttons again and access the heat output setting.
ACRIVE CHRONO LED (L1):
The LED is on when UT1 user parameter is different from OFF in the menu and weekly programming or lap time can be set.
AUGER TUBE ON LED (L2):
The LED is on whenever the Auger tube is enabled and the motor, feeding the pellets in the combustion chamber, is working. This occurs during start-up and
working mode.
REMOTE CONTROL RECEIVER LED (L3):
The LED flashes whenever the control panel receives a signal from the IR remote control to modify temperature/heat output.
ROOM THERMOSTAT LED (L4):
The LED is on whenever the room temperature is higher than the set temperature (external thermostat not in use). When using the external thermostat (if
available), the LED is lit when the thermostat temperature is reached.
TEMPERATURE SETTING LED (L5):
The LED flashes when working in the user/technician menu or while setting the temperature (SET TEMP).
DISPLAY Status/Heat Output/Parameter label DISPLAY (D1):
It shows the board status during start-up phase.
During working mode, it shows the heat output set by the user.
When modifying user/technician parameters, it shows the label of the parameter in question.
DISPLAY Status/Time/Temperature/Parameter value DISPLAY (D2):
It shows the board status during start-up phase.
During working mode, it shows the temperature set by the user.
When modifying user/technician parameters, it shows the value of the parameter in question.
USER FUNCRIONS
Stove ignition
Hold down P4 for a few seconds to switch on the stove. The display shows that the stove is on. The stove goes into the pre-ventilation/pre-heating phase for 90
seconds. The stove enters the pre-load mode for the period of time indicated by Pr45 parameter. Meanwhile, the Auger tube rotates and continues to load pellets.
At the end of the period of time set by Pr45 parameter, the system goes into the waiting phase whose duration is defined by Pr46 parameter. Then the loading
phase begins at the speed set by Pr04 parameter. The Auger tube ON LED is on indicating that the Auger tube is working. The ignition plug switches off when
fume temperature exceeds value under parameter Pr13, increasing by a gradient of approx. 3 C°/ minute.
Pellet manual loading
Press P5 and P6 buttons simultaneously to load the pellets. This function is available only when the stove is switched off and cold.
Fire on
Once fume temperature has reached and exceeded Pr13 parameter value, the stove goes into the switching on mode (ACC). In this phase temperature stabilises
for a period of time set by Pr02 parameter. In case the contrary is arrested and the error message (ALAR).
Stove operational
Once fume temperature has reached and exceeded Pr13 parameter value, maintaining it for the period of time set by Pr02 parameter, the stove enters the normal
working mode. The upper display shows the heat output set by means of P5 and P6 buttons, while lower display shows room temperature.
Changing set heat output
During the normal operating mode (stove running) the user can change the heating capacity by means of the buttons P6 (increase) and P5 (decrease). The set
heating capacity is displayed on the top screen.
Changing set room temperature
Press SET button (P3) to change room temperature and visualise the set room temperature (SET TEMP). Press P1 and P2 buttons to increase or decrease,
respectively, the temperature value.
The new value is saved after approx. 3 seconds and the display goes back to normal.
Press P3 button (SET) to visualise the set room temperature (SET TEMP).
It will remain on the display for about 2 seconds.
When the set room temperature value is reached, the stove heat output is automatically set to the minimum value. ECO (Economy) message appears on the
upper display and the room thermostat LED switches on.
Summary of Contents for ANGLE
Page 2: ......
Page 5: ...F 1 F 2 F 3 F 4...
Page 6: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 37: ...10 CERTIFICA...
Page 39: ......
Page 42: ...F 1 F 2 F 3 F 4...
Page 43: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 75: ......
Page 77: ......
Page 80: ...F 1 F 2 F 3 F 4...
Page 81: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 113: ......
Page 115: ......
Page 119: ...F 1 F 2 F 3 F 4...
Page 120: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 151: ......
Page 153: ......
Page 157: ...F 1 F 2 F 3 F 4...
Page 158: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 189: ......
Page 191: ......
Page 194: ...F 1 F 2 F 3 F 4...
Page 195: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 227: ......
Page 229: ......
Page 233: ...F 1 F 2 F 3 F 4...
Page 234: ...F 5 F 6 F 7 14 24 26 0 p 3 spento LUNEDI 07 03 2016 11 54 18 2 C Spento 12 A NORMALE 34...
Page 266: ......
Page 268: ......
Page 303: ......
Page 305: ......