background image

www.nie-tech.com   

COMMANDCLASS 

Risk of Fire

Risk of Electrical Shock

Risk of Burns 

CAUTION - PLEASE READ!

This device (ZW39) is intended for installation in accordance with 

the National Electric Code and local regulations in the United 

States, or the Canadian Electrical Code and local regulations in 

Canada. If you are unsure or uncomfortable about performing 

this installation consult a qualified electrician.

Please exercise EXTREME CAUTION when using Z-Wave devices 

to control appliances. Reason being is because the appliance you 

want to control may be in a separate room and if unintentional 

behavior occurs (such as adevice turning on or off - either 

intentionally via schedules, or unintentionally via network error) 

this event may lead to a hazardous condition. For these reasons, 

please note the following suggestions:
1) Do not include Z-Wave devices in Groups or Scenes if they 

control appliances.

2) Do not use Z-Wave devices to control electric heaters  or any 

other appliances which may present a hazardous condition due 

to unattended, unintentional,  or automatic power control

WARNING - SHOCK HAZARD

TURN OFF THE POWER 

to the circuit for the switch and lighting 

xture at the service panel (circuit breaker) prior to installation.

ALL WIRING CONNECTIONS MUST BE MADE WITH THE POWER 

OFF 

to avoid personal injury and/or damage to the switch. 

Please DO NOT use this switch to control Medical or Life Support 

equipment. Z-Wave devices should never be used to control the 

On/Off status of Medical and/or Life Support equipment.

OTHER WARNINGS

MEDICAL EQUIPMENT

CONTROLLING APPLIANCES

Parameter Settings

This device complies with part 15 of the FCC and Industry Canada 

license-exempt RSS standard(s). Operation is subjected to the 

following two conditions:

(1) this device may not cause harmful interference, and (2) this device 

must accept any interference received, including interference that 

may cause undesired operation.

                    This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment 

generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions may cause 

harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or 

more of the following measures:

— Reorient or relocate the receiving antenna.

— Increase the separation between the equipment and receiver.

— Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

— Consult the dealer or an experienced radio/TV technician for help.

                                                 To comply with the FCC RF exposure compliance 

requirements, no change to the antenna or the device is permitted. 

Any change to the antenna or the device could result in the device 

exceeding the RF exposure requirements and void user’s authority to 

operate the device.

                                 The manufacturer is not responsible for any radio or TV 

interference caused by unauthorized mod

ificati

ons to this equipment. 

Such modi

cations could void the user’s authority to operate the 

equipment.

FCC / IC

FCC NOTE: 

NOTE: 

Important note: 

GENERIC DEVICE CLASS:  

11 - GENERIC_TYPE_SWITCH_MULTILEVEL

SPECIFIC DEVICE CLASS:  

01 - SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL

COMMANDCLASS:

5E - COMMAND_CLASS_ZWAVEPLUS_INFO

26 - COMMAND_CLASS_SWITCH_MULTILEVEL

27 - COMMAND_CLASS_SWITCH_ALL

70 - COMMAND_CLASS_CONFIGURATION

85 - COMMAND_CLASS_ASSOCIATION

8E - COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION

59 - COMMAND_CLASS_ASSOCIATION_GRP_INFO

55 - COMMAND_CLASS_TRANSPORT_SERVICE

86 - COMMAND_CLASS_VERSION

72 - COMMAND_CLASS_MANUFACTURER_SPECIFIC

5A - COMMAND_CLASS_DEVICE_RESET_LOCALLY

73 - COMMAND_CLASS_POWERLEVEL

9F - COMMAND_CLASS_SECURITY_2

6C - COMMAND_CLASS_SUPERVISION

7A - COMMAND_CLASS_FIRMWARE_UPDATE_MD

V3.0 2020/7/16

Multilevel maximum  value can be set (ALL):

 

This parameter can access you to set Quick press the switch 

button 5 times Min / Max brightness level setting.

Operation:

  quickly press 5x to change this parameter .

(LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter=9, Size=1, Value=0    Disable

                                                            Value=1  

                                                                     .

                                                             Value=99  

        Default = 99

On or off dimmer speed control by parameter 7:

  

This parameter can access you to set the dimmer speed is 

controlled by parameter 7 or turn on/off instantly without any 

dim. (Only when turn ON/OFF the light)

Operation:  

Set up on the hub. 

(LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter=10, Size=1, Value=0    Control by parameter 7

                                                               Value=1     On/off instantly

        Default = 0

Dimmer speed

 

This parameter can access you to set the time from maximum 

brightness to minimum brightness or minimum brightness to 

maximum brightness. 

(Only when hold to change the 

brightness or control from HUB).

Operation:  

Set up on the hub. 

(LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter=11,  Size=1,  Value=1 from 0x63 to 0x00 or from 

0x00 to 0x63 need 1s

                                                                 Value=2  from 0x63 to 0x00 or from 

0x00 to 0x63 need 2s

                                                                           .

                                                                 Value=10  from 0x63 to 0x00 or from 

0x00 to 0x63 need 99s

       Default = 4

Scene function

 --- scene 1: Tap 2x 

LED indicator: 

This parameter can access you to choose the led indicator to 

be on when the switch(light) is on/off, or LED indicator 

remains on/off all times. 

Operation: 

  quickly press 6 times to change this parameter .

 (LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter=1, Size=1, Default =0   

                                        Value=0   Load Off, Indicator LED On

                                        Value=1    Load On, Indicator LED Off

                                        Value=2    Always Off

                                        Value=3    Always On   

Auto Turn-OFF Timer: 

This parameter can access you to set a timer to make the 

switch turn off automatically after the switch turned on.The 

numberentered as value corresponds to number of minutes.

Operation: 

 Set up on the hub. 

(LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter =2, Size=4, Values: 0 – 65535 (Min); 

         Defualt V=0      Turn off outlet

 Auto Turn-ON Timer: 

This parameter can access you to set a timer to make the 

switch turn on automatically after the switch turned off.The 

numberentered as value corresponds to number of minutes. 

Operation: 

 Set up on the hub. 

 (LED flashes 2 times when the configuration parameter 

changed.)  

     Parameter =4, Size=4, Values: 0 – 65535 (Min); 

     Defualt V=0    Turn on outlet

Restores state after power failure:

 

This parameter can access you to set the switch to be on/off 

after power failure.

Operation: 

 quickly press 10 times  to change this parameter .

(LED flashes 2 times when the configuration parameter 

changed.)   

 --- Parameter=6, Size=1, Value=0     Output off  

                                                             Value= 1     Output on

                                                             Value= 2   Restores state after power 

failure

Dimming speed:

  

This parameter can access you to set the time from maximum 

brightness to minimum brightness or minimum brightness to 

maximum brightness 

(Only when turn ON/OFF the light )  

Operation:  

Set up on the hub.  

(LED flashes 2 times when the configuration parameter 

changed.)  

 --- Parameter=7, S=1, V=XX(0x01—0x63)  Defualt V=1

Multilevel minimum  value can be set (ALL)

This parameter can access you to set Quick press the switch 

button 5 times Min / Max brightness level setting.

Operation:  

quickly press 5x  to change this parameter .

(LED flashes 2 times when the configuration parameter 

changed.)

 --- Parameter=8, Size=1, Value=0    Disable

                                                             Value=1  

                                                                     .

                                                              Value=99  

          Default = 10