background image

– 9 –

1. Open the device.

AAA

AAA

3. Close the device again.

2. Insert the batteries. 

Pay attention to the correct polarity!  

7.3  Inserting batteries

Summary of Contents for 42 600 127 112 57

Page 1: ...www eurotronic org Made in Germany Installation Operation Guide Temperature Humidity Sensor Z Wave Plus EN...

Page 2: ...ting locations 8 7 2 Mounting 8 7 3 Inserting batteries 9 7 4 Add to a Z Wave network Inclusion 10 7 5 Remove from a Z Wave network Exclusion 10 7 6 Factory reset 10 8 Z Wave 11 Content 9 Association...

Page 3: ...nual 1 Included in delivery Temperature Humidity Sensor Z Wave Plus 2x AAA Batteries AAA AAA 2x Sticky tape Quick Start Manual NOTE Please check the scope of delivery for completeness and intactness N...

Page 4: ...send the device to the Service Department Never attempt to recharge non rechargeable batteries and do not short circuit or open them This could result in the risk of overheating fire or bursting Neve...

Page 5: ...Swiss sensor technology Multicolor LED Returns the measured temperature C and humidity as well as the dew point C Supports Z Wave Plus S2 security encryption Battery operation with 2x AAA batteries Mi...

Page 6: ...lusion or exclusion commands Network hold for 10 seconds Factory resets the Temperature Humidity Sensor Z Wave Plus 5 2 LEDs Color State Meaning red lights constantly for 5 seconds A task has failed g...

Page 7: ...turn into a lower level of security A Security Enabled Z Wave Controller must be used to fully utilize the Temperature Humidity Sensor Z Wave Plus Communication to a Sleeping device Wakeup This devic...

Page 8: ...or at the wall 7 1 Recommended mounting locations 7 2 Mounting Attach your Temperature Humidity Sensor Z Wave Plus to the wall The optimum installation height is 1 50 m above the ground Do not install...

Page 9: ...9 1 Open the device AAA AAA 3 Close the device again 2 Insert the batteries Pay attention to the correct polarity 7 3 Inserting batteries...

Page 10: ...ion is active the LED is blinking green If the inclusion was successful the green LED will light up for 5 seconds Otherwise the red led will light up for 5 seconds to indicate failure Press and hold t...

Page 11: ...s information about manufacturer and product 1 S U S0 S2 Multilevel Sensor Provides sensor readings 5 S U S0 S2 Power Level Used to alter the rf power required by Z Wave 1 S U S0 S2 Security Allows en...

Page 12: ...by delta 0 1 C 5 0 C default 0x05 2 1 Humidity on Change Reporting 0x00 No on change reporting only time based reports 0x01 0x0A report if humidity changed by delta 1 10 default 0x05 3 1 Unit Tempera...

Page 13: ...sor Z Wave Plus measures the humidity and automatically reports sensor read ings to associated devices Per default the reporting threshold is 5 This parameter can be altered via configuration command...

Page 14: ...bristles or sharp or metallic cleaning objects such as knives hard spatulas and the like These can damage the surfaces Clean the Temperature Humidity Sensor Z Wave Plus with a soft dry cloth 15 Cleani...

Page 15: ...EU declaration of conformity is available at the following internet address https eurotronic org service downloads 17 Disposal The 24 months warranty period begins at the day of purchase Please keep...

Reviews: