MM850592 ed. 01 - Mini MMX II
8
DATA HOLD BUTTON
The Data Hold function allows the meter to "freeze" a measurement for later reference.
1. Press the DATA HOLD button to “freeze” the reading on the indicator. The indicator “HOLD” will be
appear in the display.
2. Press the DATA HOLD button to return to normal operation.
RELATIVE BUTTON
The relative measurement feature allows you to make measurements relative to a stored reference value. A
reference voltage, current, etc. can be stored and measurements made in comparison to that value. The
displayed value is the difference between the reference value and the measured value.
1. Perform any measurement as described in the operating instructions.
2. Press the RELATIVE button to store the reading in the display and the "REL" indicator will appear on
the display.
3. The display will now indicate the difference between the stored value and the measured value.
4. Press the RELATIVE button to return to normal operation.
BACKLIGHT BUTTON
1. Press the BACKLIGHT button 2 seconds the display light ON
2. Press BACKLIGHT button again to exit the light mode.
Hz/%duty BUTTON
Press Hz/Duty Button to choose Frequency or Duty Cycle in the range of Frequency; Press Hz/%Duty
Button to measure Frequency or Duty Cycle while measures voltage or Current, the Voltage/Current
requirement and range of Frequency see the following form, press Hz/%Duty Button to return to
measurement of Voltage or Current.
Range
(DC/AC )
Sensitivity Frequency
width
4V
≥
2V rms
5Hz~10kHz
≥
15V rms
5Hz~20kHz
40V, 400V
≥
25V rms
5Hz~100kHz
1000V/1000V
≥
450V rms
50Hz~1kHz
400mA
≥
5mA rms
5Hz~5kHz
10A
≥
5A rms
5Hz~1kHz
Note: The above data only for reference.