The proportional part of the P+I algorithm is executed immediately before each run of the
current loop, thus ensuring minimum time lag and therefore maximum bandwidth.
&RPELQHG
#
$QDORJ
#
7DFKR
#2#
(QFRGHU
#
)HHGEDFN
By using the analog tacho f/b on the Proportional part of the P + I algorithm and the encoder f/b
on the Integral part (using similar principle as in the current loop), the Converter combines
maximum transient response with the increased steady-state accuracy of the digital feedback.
&XUUHQW
#
'HPDQG
#
5DWH
#
/LPLW
#+
GL
2
GW
,
Access to the di/dt limit is currently reserved for Eurotherm Drives personnel only in the
Reserved Menu.
This is a limit imposed on the rate of change of the current demand. It is to be used for motors
with commutation limitations, mechanical systems that cannot absorb rapid torque transients and
also as a means of limiting current overshoot for large current swings (e.g. 0
➠
200%). The
default value is set at 35% (i.e. maximum allowable change is 35% of FLC in 1/6 mains cycle)
which has no practical effect on the current response between 0 and 100%.
)LHOG
#
&RQWURO
6HW
0
XS
#
1RWHV
The setting of the P + I gains for the current controller is done manually in much the same way
as described in Chapter 4: “Current Loop - Manual Tuning”, and one convenient way is to
switch several times from "quench" to "standby" mode and observe the current response 0
➠
50% for rise time and overshoot.
The setting of the field weakening gains is achieved by observing the armature voltage feedback
for overshoot and settling time. The EMF GAIN parameter defaults to 0.30 (real gain of 30) and
normally lies in the region 0.20 to 0.70 (larger settings normally lead to instability). The EMF
LEAD parameter should be set at around the time constant for the field current loop. It defaults
to 2.00 (200 msec). Finally, the EMF LAG parameter defaults to 40.00 (4000 msec) and it
should generally lie in the region of 10 to 50 times the "emf lead".
The tuning of the field weakening loop is also very dependent on the acceleration rate through
base speed and visa-versa. If armature voltage overshoot is a problem for rapid acceleration
rates, then the use of the "feedback lead/lag" compensator is recommended to limit the overshoot
as discussed above. If not, then the default values for the above bemf fbk gains are
recommended (i.e. disabled) which will probably allow further increase in the forward path
transfer function gains ("emf gain" and "emf lead") for faster field response.
In summary, the increased attenuation at the higher frequencies will allow an increase in the gain
whilst maintaining the desired phase margin. Bearing in mind that the negative angle of the
compensator lowers the angle curve, in order to maintain the desired phase margin (45 to 60
degrees) a reduction in the phase-margin frequency is required. This is the frequency at which
the log magnitude curve crosses the 0 db line. Since the phase-margin frequency is indicative of
the speed of response of the system, its reduction should be kept to a minimum. This is
achievable by trying to keep the value of the corner-frequency 1 / T1 as low as possible by
setting T1 at values greater than 100 msec or so. The upper limit for T1 will be dictated by the
settling time requirement.
&XUUHQW
#
&RQWURO
The field current loop can accept a demand directly from the plant and/or an outside field
weakening loop and forms the error signal which is the difference between demand and
feedback. The error signal is fed into a P + I compensator which produces the output of the field
loop, i.e. the field firing angle signal.
The firing angle signal is translated into a certain time delay from the mains zero cross point
(obtained via the same Phase-Lock-Loop as for the armature) and this results into a firing
command being issued to the field bridge every 1/2 of a mains cycle in steady-state.
Summary of Contents for 590L Series
Page 14: ... RQWHQWV RQWHQWV 3DJH RQW147 ...
Page 18: ...407 HWWLQJ 6WDUWHG 8 3 6HULHV RQYHUWHU ...
Page 42: ...6053 QVWDOOLQJ WKH RQYHUWHU 8 3 6HULHV RQYHUWHU Figure 3 6 110A and 150A Stack Assembly ...
Page 43: ... QVWDOOLQJ WKH RQYHUWHU 6054 8 3 6HULHV RQYHUWHU Figure 3 7 180A Stack Assembly ...
Page 44: ...6055 QVWDOOLQJ WKH RQYHUWHU 8 3 6HULHV RQYHUWHU Figure 3 8 270A Stack Assembly ...
Page 45: ... QVWDOOLQJ WKH RQYHUWHU 6056 8 3 6HULHV RQYHUWHU Figure 3 9 360A Stack Assembly ...
Page 46: ...6057 QVWDOOLQJ WKH RQYHUWHU 8 3 6HULHV RQYHUWHU Figure 3 10 450A Stack Assembly ...
Page 47: ... QVWDOOLQJ WKH RQYHUWHU 6058 8 3 6HULHV RQYHUWHU Figure 3 11 720A Stack Outline Drawing ...
Page 48: ...6059 QVWDOOLQJ WKH RQYHUWHU 8 3 6HULHV RQYHUWHU Figure 3 12 720A Stack Outline Drawing ...
Page 104: ...905 3URJUDPPLQJ RXU SSOLFDWLRQ 8 3 6HULHV RQYHUWHU ...
Page 118: ... 09 RQWURO RRSV 8 3 6HULHV RQYHUWHU ...
Page 154: ...45049 HUWLILFDWLRQ IRU WKH RQYHUWHU 8 3 6HULHV RQYHUWHU ...
Page 168: ...46047 6WDQGDUG DQG 2SWLRQDO TXLSPHQW 8 3 6HULHV RQYHUWHU ...
Page 170: ......