Appendix J Parameter List by Menu
App. J - 4
J
590 DRV Digital DC Drive Product Manual
TAG PARAMETER NAME MENU
DEFAULT
MIN MAX
288 EXTERNAL RESET
SETUP PARAMETERS::RAMPS
DISABLED
0
1 RW
126 MIN SPEED
SETUP PARAMETERS::RAMPS
0.00%
0 10000 RW
2 RAMP ACCEL TIME
SETUP PARAMETERS::RAMPS
10.0 SECS
1
6000 RW
3 RAMP DECEL TIME
SETUP PARAMETERS::RAMPS
10.0 SECS
1
6000 RW
118 RAMP HOLD
SETUP PARAMETERS::RAMPS
OFF
0
1 RW
5 RAMP INPUT
SETUP PARAMETERS::RAMPS
0.00%
-10000 10000 RW
286 RAMPING THRESH.
SETUP PARAMETERS::RAMPS
0.50%
0 10000 RW
422 RESET VALUE
SETUP PARAMETERS::RAMPS
0.00%
-30000 30000 RW
131 DEADBAND WIDTH
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
0 10000 RW
420 DIVIDER 0
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
419 DIVIDER 1
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
309 INPUT 0
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
100 INPUT 1
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
423 INPUT 2
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
375 LIMIT
SETUP PARAMETERS::SETPOINT SUM 1
105.00%
0 20000 RW
208 RATIO 0
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
6 RATIO 1
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
292 SIGN 0
SETUP PARAMETERS::SETPOINT SUM 1
POSITIVE
0
1 RW
8 SIGN 1
SETUP PARAMETERS::SETPOINT SUM 1
POSITIVE
0
1 RW
427 DIAMETER
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
0 10000 RO
463 EXTERNAL RESET
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
DISABLED
0
1 RW
424 LINE SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
-10500 10500 RW
425 MIN DIAMETER
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
10.00%
0 10000 RW
426 MIN SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
5.00%
0 10000 RW
453 RAMP RATE
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
5.0 SECS
1
6000 RW
437 REEL SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
-10500 10500 RW
462 RESET VALUE
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
10.00%
0 10000 RW
401 DERIVATIVE TC
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.000 SECS
0 10000 RW
418 DIVIDER 1
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
414 DIVIDER 2
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
408 ENABLE
SETUP PARAMETERS::SPECIAL BLOCKS::PID
ENABLED
0
1 RW
403 FILTER T.C.
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.100 SECS
0 10000 RW
410 INPUT 1
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.00%
-30000 30000 RW
411 INPUT 2
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.00%
-30000 30000 RW
409 INT. DEFEAT
SETUP PARAMETERS::SPECIAL BLOCKS::PID
OFF
0
1 RW
402 INT. TIME CONST.
SETUP PARAMETERS::SPECIAL BLOCKS::PID
5.00 SECS
1 10000 RW
474 MIN PROFILE GAIN
SETUP PARAMETERS::SPECIAL BLOCKS::PID
20.00%
0 10000 RW
473 MODE
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0
0
4 RW
406 NEGATIVE LIMIT
SETUP PARAMETERS::SPECIAL BLOCKS::PID
-100.00%
-10500
0 RW
407 O/P SCALER(TRIM)
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.2
-30000 30000 RW
405 POSITIVE LIMIT
SETUP PARAMETERS::SPECIAL BLOCKS::PID
100.00%
0 10500 RW
475 PROFILED GAIN
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0
0
1000 RO
404 PROP. GAIN
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
0
1000 RW
412 RATIO 1
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
413 RATIO 2
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
448 DIVIDER 0
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
1
-30000 30000 RW
466 DIVIDER 1
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
1
-30000 30000 RW
444 INPUT 0
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
0.00%
-30000 30000 RW
443 INPUT 1
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
0.00%
-30000 30000 RW
445 INPUT 2
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
0.00%
-30000 30000 RW
449 LIMIT
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
100.00%
0 20000 RW
447 RATIO 0
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
1
-30000 30000 RW
446 RATIO 1
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
1
-30000 30000 RW
451 SPT SUM OUTPUT
SETUP PARAMETERS::SPECIAL BLOCKS::SETPOINT SUM 2
0.00%
-20000 20000 RO
438 TAPER
SETUP PARAMETERS::SPECIAL BLOCKS::TAPER CALC.
0.00%
-10000 10000 RW
452 TAPERED DEMAND
SETUP PARAMETERS::SPECIAL BLOCKS::TAPER CALC.
0.00%
0 10000 RO
439 TENSION SPT.
SETUP PARAMETERS::SPECIAL BLOCKS::TAPER CALC.
0.00%
0 10000 RW
440 TENSION TRIM
SETUP PARAMETERS::SPECIAL BLOCKS::TAPER CALC.
0.00%
-10000 10000 RW
441 TOT.TENS.DEMAND
SETUP PARAMETERS::SPECIAL BLOCKS::TAPER CALC.
0.00%
-10000 10000 RO
434 OVER WIND
SETUP PARAMETERS::SPECIAL BLOCKS::TORQUE CALC.
ENABLED
0
1 RW
Summary of Contents for 590 DRV Digital
Page 2: ......
Page 16: ...1 4 Chapter 1 Introduction 1 590 DRV Digital DC Drive Product Manual ...
Page 22: ...2 6 2 Chapter 2 Identification 590 DRV Digital DC Drive Product Manual ...
Page 45: ...Figure 3 20 Wiring Circuit Diagram for 590 DRV Digital Drive ...
Page 77: ...5 22 5 590 DRV Digital DC Drive Product Manual Chapter 5 Troubleshooting ...
Page 103: ...App A 18 A Appendix A Technical Description 590 DRV Digital DC Drive Product Manual ...
Page 107: ...B Appendix B Using the Man Machine Interface App B 4 590 DRV Digital DC Drive Product Manual ...
Page 149: ...Appendix C Setup Parameters 590 DRV Digital DC Drive Product Manual App C 42 C ...
Page 173: ...Appendix D I O Configuration System Menu App D 24 D 590 DRV Digital DC Drive Product Manual ...
Page 174: ...Figure D 20 590 DRV Digital DC Drive Software Block Diagram t t t t ...
Page 202: ...App F 18 Appendix F Spare Parts List 590 DRV Digital DC Drive Product Manual F ...
Page 208: ...Appendix G RS232 System Port P3 590 DRV Digital DC Drive Product Manual App G 6 G ...
Page 250: ...Appendix J Parameter List by Menu App J 8 J 590 DRV Digital DC Drive Product Manual ...
Page 258: ...Appendix K Parameter List by Parameter Name 590 DRV Digtial DC Drive Product Manual App K 8 K ...