background image

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Distance to Combustible materials 

Combustible materials should not be located where the heat dissipating through the walls of fireplaces or 
flues  could  ignite  it.  Therefore  when  installing  the  stove  in  the  presence  of  combustible  materials  due 
account  must  be  taken  of  the  guidance  on  the  separation  of  combustible  material  given  in  Building 
Regulations Approved Document J and also in these stove instructions. 

 

WF32/UNIQ32 INSET

 

WF23/UNIQ23 INSET

 

Distance to combustible materials rear 

300mm 

200mm 

Distance to combustible materials side 

200mm 

350mm 

Distance to soft furnishing in front 

1100mm 

1100mm 

The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the 
stove

Typical installation of 
an inset stove 

Summary of Contents for WESTFIRE UNIQ 32

Page 1: ...ng operation a glove is provided for use when the stove is hot We recommend that a guard should be used for the protection of the young elderly and vulnerable Do not burn rubbish or pre sawn treated t...

Page 2: ...rent Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may...

Page 3: ...ore than 160 mm x 160 mm Remedial action should be taken if required seeking expert advice If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accord...

Page 4: ...WF 23 UNIQ 23 BUILDERS APERTURE SIZE WF 32 UNIQ 32 BUILDERS APERTURE SIZE WF23 UNIQ 23 WF 32 UNIQ 32 DOOR REMOVAL Narrow frame model Wide frame model 420mm...

Page 5: ...e back and sides with a 6 1 vermiculite to cement mix or any other good quality non combustible insulation material It is important that the back and sides of the stove are well insulated VII Connect...

Page 6: ...guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions WF32 UNIQ32 INSET WF23 UNIQ23 INSET Distance to combustible ma...

Page 7: ...to each side measuring from the door of the combustion chamber Combustion air supply In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in w...

Page 8: ...WESTFIRE WF23 UNIQ 23 INSET MODEL...

Page 9: ...WESTFIRE WF32 UNIQ 32 INSET NARROW FRAMED MODEL 405mm 810 00mm...

Page 10: ...WESTFIRE WF32 UNIQ 32 INSET WIDE FRAMED MODEL...

Page 11: ...be replaced Commissioning and handover Ensure loose parts are fitted in accordance with the instructions given in the instruction booklet On completion of the installation allow a suitable period of...

Page 12: ...using paper To light your stove 1 Place a few smaller pieces of dry wood kindling in the stove on top of the non toxic firelighters place one or two small dry split split logs on top 2 Fully slide op...

Page 13: ...to nominal temperature Basic Positions of dampers during operation nominal Secondary air Primary air WF23 UNIQ 23 60 open closed WF 32 UNIQ 32 30 open closed You will need to become familiar with you...

Page 14: ...n WESTFIRE WF 32 UNIQ32 INSET CONTROLS on WESTFIRE WF 23 UNIQ 23 INSET Door operation When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from poss...

Page 15: ...stoves need to have the ash removed from the stove at regular intervals Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours To clean the outside of t...

Page 16: ...wn Brick 1 is held in place with a steel pin Left right mid baffle bricks 2 3 positioned with full angled edge at front and part angled edge on the outside Bricks 2 3 need to be fitted lower down and...

Page 17: ...is then supported by left side brick 6 Front base brick 11 fitted Right base brick 7 positioned Right side brick 8 positioned on top of right base brick 7 Right mid baffle brick 3 must be held up to e...

Page 18: ...FIRE BRICK INSTALLATION SEQUENCE WESTFIRE UNIQ 23 continued Grate 13 fitted Log retainer 14 fitted Grate support 12 fitted...

Page 19: ...1 Outer Top Baffle Brick 2 Left Angled Side Brick 3 Right Angled Side Brick 4 Rear Brick 5 Left Side Brick 6 Right Side Brick 7 Left Base Brick 8 Right Base Brick 9 Rear Base Brick 10 Front Base Brick...

Page 20: ...ck 7 fitted Right base brick 8 fitted Rear base brick 9 fitted Front base brick 10 fitted Base grate 11 fitted Log retainer 12 fitted Inner top baffle brick 13 Angled parallel edge at rear resting on...

Page 21: ...n relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney...

Page 22: ...prior to lighting up after a prolonged shutdown period If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may...