EUROSTER 11W Installation And Operation Manual Download Page 2

EUROSTER 11W 

 USER MANUAL 

 

 

2

 

4.

 

VISIBLE ELEMENTS 

 

1.

 

230 V 50 Hz power cable of the controller 

2.

 

230 V 50 Hz power cable of the CH pump 

3.

 

230 V 50 Hz power cable of the blower 

4.

 

Thermal protection cable 

5.

 

Input for temperature sensor cable 

6.

 

Power switch 

7.

 

LCD 

8.

 

Knob 

The display backlight turns off by default after one minute following the end of the controller 
operation. The controller enables turning permanent backlight on. (section 8)  

5.

 

CONTROLLER INSTALLATION 

Hazardous voltage is present inside the controller and on its output cables. 
Therefore,  it  is  absolutely  forbidden  to  install  the  device  prior  to 
disconnecting  its  power  supply.  Such  installation  must  be  performed  by 
qualified  technicians  only.  Do  not  install  a  controller  showing  signs  of  any 
mechanical damage.

 

a)

 

mounting the controller: 

 

using  a  pair  of  screws  mount  the  controller  box  on  a  wall  or  any  other  supporting 
structure (screw anchors with screws are supplied with the controller); 

 

using fasteners fix controller cables to the wall. 

b)

 

fixing the sensor: 

 

do not immerse the sensor in liquids nor install them at flue gas outlets to the 
stack;

 

 

fix  the  sensor  on  the  boiler  in  a  point  specially  designed  for  that  purpose  or  on  an 
unshielded outlet pipe of the CH boiler (as close to the boiler as possible); 

 

using hose clip tighten the sensor to the pipe and cover it with thermal insulation. 

c)

 

connecting the power cable to the pump: 

 

connect the yellow or yellow-green wire (protective cable) with the terminal (

); 

 

connect the blue wire to the terminal (N); 

 

connect the brown wire to the terminal (L); 

d)

 

connecting the power cable to the blower: 

 

connect the yellow or yellow-green wire (protective cable) with the terminal (

); 

 

connect the blue wire to the terminal (N); 

 

connect the brown wire to the terminal (L); 

e)

 

checking the connection: 

 

check  whether  the  cables  have  been  connected  correctly  and  tighten  the  covers  of 
terminal boxes. 

f)

 

connecting the controller: 

 

after securing the cables against any accidental rupture,

 connect the power cable 

to a 230 V / 50 Hz socket with an earthing pin. 

 

g) connecting the thermal protection 

 

 

fix a bimetallic circuit breaker along with a temperature sensor on the boiler in a point 
specially designed for that purpose or on an unshielded outlet pipe of the CH boiler (as 
close to the boiler as possible); 

 

put  the  bimetallic  circuit  breaker  against  the  pipe 

(the  side  without  90°C  label 

facing  the  pipe)

,  using  hose  clips  fix  it  tight  to  the  pipe  and  cover  with  thermal 

insulation.

 

Summary of Contents for 11W

Page 1: ...urnace and controls the operation of the CH circulation pump EUROSTER 11W controller is equipped with an ANTI STOP function that prevents seizing of an idle pump rotor It automatically turns the pump...

Page 2: ...n the boiler in a point specially designed for that purpose or on an unshielded outlet pipe of the CH boiler as close to the boiler as possible using hose clip tighten the sensor to the pipe and cover...

Page 3: ...ter displayed while previewing or changing the setting 2 Boiler temperature sensor icon 3 Manual operation mode icon lit while the temperature is manually adjusted 4 Alarm icon blinks in case of alarm...

Page 4: ...select the number 0 or 1 and confirm Selecting 0 enables to change screen backlight functions without restoring factory defaults Selecting 1 restores factory settings bl Backlight will be displayed an...

Page 5: ...gh to prevent the boiler temperature rise 6 Time interval between successive blow throughs This is the time passing between the end of the blow through cycle and the start of a new cycle It should be...

Page 6: ...t then press it and hold down until the blower is started turn the controller power off and on Firing up is terminated if the boiler temperature is lower than the set temperature 1 by at most a half o...

Page 7: ...The CH pump is turned off if the boiler temperature drops below the preset value by a half of the preset hysteresis T boiler TCH HCH 2 Power Alarm Temperature In case the temperature measured by the...

Page 8: ...oad 2 A 230 V 50 Hz Maximum blower output load 0 5 A 230 V 50 Hz Maximum power consumption 1 6 W Temperature measurement range from 5 C to 110 C CH temperature adjustment range from 20 C to 80 C Boile...

Page 9: ...e every effort to ensure that this controller lifetime is as long as possible However the device is subject to natural wear If the device would not meet your requirements any more you are kindly reque...

Page 10: ...y by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unauthor...