EUROSTER 11W Installation And Operation Manual Download Page 1

EUROSTER 11W 

 USER MANUAL 

 

 

1

 

EUROSTER 11W

 

Installation and operation manual

 

 

 

MANUFACTURER: P.H.P.U. AS, ul. Polanka 8a/3, 61-131 

Poznań, Poland

 

 

Manual version: 11.05.2013.

 

1.

 

INTRODUCTION 

In order to  ensure proper  operation  of the controller and of the CH  system, please read this 
manual carefully. 

2.

 

APPLICATION 

EUROSTER  11W

  is  a  state-of-the-art  microprocessor-based  controller  designed  for 

interoperation  with  Central  Heating  (CH)  coal-  and  pulverized  coal-fired  boilers  in  systems 
equipped with furnace blowers. 
The controller measures the temperature of water in the boiler and adjusts the air flow to the 
furnace and controls the operation of the CH circulation pump. 

 

EUROSTER  11W  controller  is  equipped  with  an  ANTI-STOP  function  that  prevents 
seizing  of  an  idle  pump  rotor. 

It  automatically  turns  the  pump  on  for  30 seconds  every 

14 days 

when 

the 

heating 

season 

is 

over. 

Keep the controller turned on to allow the function operation after the heating season. 

3.

 

CONTROLLER FUNCTIONS 

 

ensure smooth adjustment of the blower rotational speed 

 

ensure optimum operation of the boiler 

 

prevent boiler condensation (sweating) 

 

prevent boiler overheating 

 thermal protection 

 

provide frost protection 

 

provide the Anti-Stop function 

 protection of the blower and pump against seizure 

 

ensure comfortable presetting with a knob 

 

perform operation tests of the pump and of the blower 

 

provide temperature readings correction 

 

Summary of Contents for 11W

Page 1: ...urnace and controls the operation of the CH circulation pump EUROSTER 11W controller is equipped with an ANTI STOP function that prevents seizing of an idle pump rotor It automatically turns the pump...

Page 2: ...n the boiler in a point specially designed for that purpose or on an unshielded outlet pipe of the CH boiler as close to the boiler as possible using hose clip tighten the sensor to the pipe and cover...

Page 3: ...ter displayed while previewing or changing the setting 2 Boiler temperature sensor icon 3 Manual operation mode icon lit while the temperature is manually adjusted 4 Alarm icon blinks in case of alarm...

Page 4: ...select the number 0 or 1 and confirm Selecting 0 enables to change screen backlight functions without restoring factory defaults Selecting 1 restores factory settings bl Backlight will be displayed an...

Page 5: ...gh to prevent the boiler temperature rise 6 Time interval between successive blow throughs This is the time passing between the end of the blow through cycle and the start of a new cycle It should be...

Page 6: ...t then press it and hold down until the blower is started turn the controller power off and on Firing up is terminated if the boiler temperature is lower than the set temperature 1 by at most a half o...

Page 7: ...The CH pump is turned off if the boiler temperature drops below the preset value by a half of the preset hysteresis T boiler TCH HCH 2 Power Alarm Temperature In case the temperature measured by the...

Page 8: ...oad 2 A 230 V 50 Hz Maximum blower output load 0 5 A 230 V 50 Hz Maximum power consumption 1 6 W Temperature measurement range from 5 C to 110 C CH temperature adjustment range from 20 C to 80 C Boile...

Page 9: ...e every effort to ensure that this controller lifetime is as long as possible However the device is subject to natural wear If the device would not meet your requirements any more you are kindly reque...

Page 10: ...y by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unauthor...

Reviews: