User manual - Compact-Pro 30 BASIC
202204-585-ENG
P10
4. USE OF THE MACHINE
4.1. PREREQUISITES
•
The electric connection has to be 230 V - 16 A - 50 or 60 Hz with a 3 x 2,5 mm² cable reel of 40m
maximum, completely unreeled.
• Turning button (N) to MANU makes the product pump start.
• Turning button (N) to REVERSE makes the product pump turn in reverse mode.
•
In AUTO mode, the pump starts only at the opening of the lance (when the compressor in
running).
•
In MANU mode, the pump works continuously.
• After a prolonged standstill, it is possible that the pump might be blocked. If this is the case, alternately
turn the pump forwards and backwards for 5 second sequences. As soon as the engine starts to turn
normally, the pump is unblocked.
•
In order to avoid condensation (and rust) in the compressor tank, make sure to unscrew and leave open
the drain screw (I) when the machine is not in operation. Screw in only when the machine is working or
being transported.
•
Check every month that the machine’s automatic lubricator is working properly. The level of grease in the
cartridge should decrease steadily. The absence of grease can seriously damage the machine.
PRESSURE VALUES:
- Ready-to-use product: from 12 to 15 bars
- Traditional product: from 5 to 8 bars
- E.W.I. products (glue / Thick Plastic Coating) : from 40 to 60 bars (MAP 7 rotor/stator kit)
PRESSURE CONTROL AND ADJUSTMENT:
(at least once a week)
•
Install the pressure controller on the machine outlet with the valve in the open position.
•
Put water in the tank.
•
Switch the machine on (button (K)).
• Set the potentiometer to 10.
• Turn button (N) to the MANU position, the machine starts.
• Close the controller valve and read the value on the manometer (C).
•
Adjust the desired value with the 3 pump screws (tighten from the external screw to the screw on the
tank side, equally).
• Adjust by closing the valve and reading the manometer
(repeat the adjustment operation until the
correct pressure is obtained)
.
Never use petroleum-based products in the pump, as they may damage it.
Never run the pump without water or product.