Page 8
Vista 42 Indoor Gas Fireplace
rev. 110201
Installation
Section 3:
Venting
Figure 9.
Flue cover and collar removal,
Top Vented
fireplace.
Figure 9a.
Flue cover and collar installation,
Rear Vented
,
N.G. equipped fireplaces
ONLY.
Section 3-1:
CONVERTING TO REAR VENT
Use the following instructions to convert an
Vista 42
for Rear Vent use:
1. Remove the Rear flue cover and gasket (5" and 8") on the flue outlet, as
shown in
Figure 9.
2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet, as shown
in
Figure 9.
3. Install the (removed) Rear flue cover and gasket material, to the Top vent
outlet. Fasten the cover with included hardware, as illustrated
Figure 9a
.
4. Install the (5" and 8") collars to the rear vent outlet using the included hardware,
as illustrated
Figure 9a
.
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
Flue Gasket
Flue Cover Plate
European Home supplies a variety of direct venting and termination options.
The
direct vent termination location MUST be selected such that it is the highest
point in the venting assembly.
It should also be selected such that it provides the
shortest vent run possible. Should it be impossible to ensure that the termination
is the highest point or to meet the venting guidelines laid out below please contact
your European Home dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through the rear
Venting can terminate through the roof or through an exterior wall
.
Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable
.
Once the termination location has been established, refer to the
appropriate section below for installation details
All fireplaces shipped from the factory are
Top vent.
See Section 3-1 for converting the unit from top vent to rear vent.
IMPORTANT:
Straight though the wall applications shown in
Figures
3 and 5
are available for
N.G. (Natural Gas) equipped
fireplaces ONLY.
L.P equipped fireplaces see
Figure17b.
for possible vent
configuration.