Page 13
Vista 42 Indoor Gas Fireplace
rev. 110201
Installation
Figure 16b.
Corner installation.
Figure 16c.
Flex installation.
(NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the PXT-20 to suit,
and attach it to the PEL-45. Slide the fireplace into position and attach to the
termination.
45° or less Corner Installation.
Use an PTO-3 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24" compressed
length) and a frame, if appropriate.
Flex may be turned to obtain desired degree
of angle required but must not exceed 45°.
Note: Through-the-wall venting kits are also available for both the straight
and the corner installation.
The kit includes a heat shield, a PFL-12 (f/f) flexible
pipe, and a termination with or without a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
Heat Shield
Heat Shield