45
MAINTENANCE
Element4 Gas Fireplaces
European
Home
.com
WARNING
Installation and maintenance must be performed by
an authorized qualified installer, service agency or gas
supplier.
TURN OFF THE GAS before servicing the appliance. It
is recommended that a qualified service technician
perform an appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST
BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under
water. Immediately, call a qualified service technician to
inspect the unit and to replace any part of the control
system and any gas control that has been under water.
Any alteration to the product that causes soot or
carbon to form and results in damage is not the
responsibility of the manufacturer.
Inspect the external vent cap on a regular basis to make
sure that no debris, plants, trees, shrubs are interfering
with the air flow.
BURNER MAINTENANCE
The flames from the burner should be visually checked.
The flame should have a blue base and yellow tops and be
candle-like in appearance.
PILOT MAINTENANCE
The pilot flame must be visually checked. The pilot flame must
always be present when the appliance is in operation and
should appear as in Figure 50.
The pilot burner has two distinct flames, one engulfing the
thermocouple, the other reaches across to the main burner.
The area around the injector should be inspected and any lint
or foreign material must be removed with a brush or vacuum.
Pilot Injector Natural - Marking 31.2
Pilot Injector Propane - Marking 27.1
3mm
Figure 49
. Pilot Burner Detail