16
CLEARANCES
Element4 Gas Fireplaces
European
Home
.com
A
A
B
B
VENT OPENING
800cm² (124In²)
TOTAL MINIMUM
(2") 50
C
SECTION A-A
(36") 900
(36")
900
(36")
900
SECTION B-B
COMBUSTIBLE MATERIALS
NOT PERMITTED IN FRONT
OF GLASS
(2") 50
(11") 280
DETAIL C
SCALE 1 : 10
CONSTRUCTION
BEAMS NON-
COMBUSTIBLE
(TYPICAL)
TOP OF FIREPLACE
OPENING
GLASS
NON COMBUSTIBLE
MATERIAL
DETAIL C
CONVECTION GAP
CONSTRUCTION
BEAMS COMBUSTIBLE
(TYPICAL)
A typical chase enclosing a Trisore fireplace (as an example) is shown in Figure 11. Section B-B (plan view) shows the area around
the fireplace in which combustible furnishings are not permitted. Section A-A shows the clearance to NON-combustible materials.
See
ENCLOSING the FIREPLACE
for the dimensions required for the Convection Air Outlet.
KEEP THIS AREA FREE OF
COMBUSTIBLE FURNISHINGS
36”
900 mm
36”
900 mm
36”
900 mm
2”/50 mm
Figure 11
WARM AIR OUTLET
REQUIRED