33
Maintenance
Always switch off the generator and let it cool down completely before carrying out
any maintenance tasks.
Maintenance schedule
Item
Comment
Before
each
use
1
st
time
after
25
hours
Every
50
hours
Every
100
hours
Spark plug
Check condition, adjust
distance and clean. If
necessary, replace.
*
Motor oil
Check oil level
*
Change the oil
*
*
Air filter
Clean and if necessary,
replace
*
Fuel filter
Clean and if necessary,
replace
*
Fuel hose
Check for bends and damage.
If necessary, replace
*
Exhaust
system
Check for leakage. If
necessary, close the sealer
again or replace.
*
Check the exhaust grate. If
necessary, clean or replace.
*
Carburettor
Check the operation of the
choke.
*
Cooling
system
Check to fan for damage.
*
Start system
Check the operation of the
pulling cord.
*
Couplings
and valves
Check all the couplings,
connections and valves and
correct their position if
necessary.
*
CAUTION! To prevent the generator from starting by accident during maintenance,
always first remove the spark plug or disconnect the spark plug cable.