background image

 
 

10 

Position 

Excess moisture will travel throughout  your home,  in  the same way that  cooking smells 
waft to every room in the house. For this reason, the dehumidifier should be positioned, 
so that it can draw this moist air towards it from all over the home.  
Alternatively, if you have a serious problem in one area you can begin by positioning the 
dehumidifier close to this area and later moving it to a more central point.  
When  positioning  the  dehumidifier,  ensure  that  it  is  placed  on  a  level  surface  and  that 
there is a minimum of 10 cm (4") of space on either side of the unit to allow for efficient 
airflow.   
If you move the unit, it should first be switched off and the water tank emptied.  
We do not recommend the use of an extension lead, so please try to ensure that the unit 
is sufficiently close to a fixed mains  socket. If it is necessary to use am extension lead, 
use one with earthing and please ensure the diameter of the wires of the cable is at least 
1,5 mm2. 
Don’t place the device near a heater, stove or other heat source, and not in full sunshine. 
When  the  dehumidifier  is  in  operation,  outside  doors  and  windows  should  be  closed 
when  necessary  for  most  efficient  use.  However,  do  not  use  the  device  in  a  sealed  or 
very small space. 

 
 

Operation 

1.  Turn the

 

on / off button

also

 

humidistat

completely

 to 

OFF /

 

MIN

 

mode: the device

 

is 

now

 

deactivated

Plug into

 

a

 

earthed

 mains 

socket

, corresponding to 

the 

specifications on

 

the rating label

 

2.  Turn the

 

humidistat

 

clockwise

 

direction

 

MAX

At one point

 

you will hear

 

the 

compressor

 

catch on and

 

the device

 

starts

 

its operation

The further you turn

 

the

 

knob 

to

 

MAX

, the lower 

you set the

 

humidity

.

 

3.  When

 

the unit

 

reaches

 

the set

 

humidity

, it will 

automatically stop

 

his works

; when 

the

 

humidity

 

rises above the

 

set value,

 

the machine will turn on again. 

4.  When

 

you turn

 

the on / off

 button completely to 

MAX, the unit will operate 

continuously

by turning

 te button back to 

OFF

 

/

 

MIN you switch off the device. 

  

Press the ON / OFF button again to switch it off again. 

5.  After use, always remove the

 

plug from the socket

.

 

 
 
Drainage 

While the water tank is full, the compressor will stop for 
self-protection  and  the  water  full  indicator  will  turn  into 
red. 
To move the water tank, pull it out squarely from the unit. 
After  empting  the  water  tank,  place  the  water  tank  into 
space.  Make  sure  it  is  properly  positioned,  in  order  for 
the  'water  full'  sign  to  go  out  and  your  dehumidifier  is 
operating.  

Please  note

:  in  case,  the  water  tank  has  not  been 

positioned well,  the water full indicator will turn into red. 
The equipment does not work.  

 

 

Summary of Contents for 37.235.9

Page 1: ...NL Gebruiksaanwijzing EN Instruction manual DE Bedienungsanleitung FR Manuel d utilisation LO20 Art nr 37 235 9 NL Luchtontvochtiger EN Dehumidifier DU Luftentfeuchter FR D shumidificateur...

Page 2: ...len betyder f r ej vert ckas NO Dette symbolet p apparatet betyr M ikke dekkes til FI T m laitteessa oleva symboli tarkoittaa ei saa peitt HU A k sz l k n l v szimb lum jelent se ne takarja le CS Tent...

Page 3: ...reiniging altijd een uur rusten voor u de stroom weer aansluit Zorg ervoor dat de luchtinvoer en uitlaatopeningen altijd vrij zijn van blokkades en vuil Voorkom dat vreemde voorwerpen of vingers door...

Page 4: ...veiligheid Er dient op te worden toegezien dat kinderen niet met het apparaat spelen Wanneer de temperatuur lager dan 10 C is en de luchtvochtigheid is vrij laag is het niet nodig te ontvochtigen BELA...

Page 5: ...cht afgesloten of zeer kleine ruimte Ingebruikname 1 Draai de aan uitknop tevens hygrostaat helemaal op de OFF MIN stand het apparaat staat nu uitgeschakeld Steek de stekker in een passend geaard stop...

Page 6: ...houd Neem altijd de stekker uit het stopcontact voordat u het apparaat schoonmaakt of er onderhoud aan uitvoert Het schoonmaken van de buitenzijde Gebruik een zachte doek om het apparaat schoon te wis...

Page 7: ...beschadigingen scheurtjes of vervormingen vertoont Staat het apparaat wel stabiel en volkomen horizontaal Het apparaat maakt teveel lawaai Controleer of het wel stevig vlak en horizontaal staat Is het...

Page 8: ...ructed Prevent foreign objects or fingers from entering the equipment via the venting or exhaust openings as this may lead to electric shock fire or damage The supply voltage and utility frequency spe...

Page 9: ...ity is relatively low it is not necessary to dehumidify IMPORTANT Do not use this unit at ambient temperatures below 5 C to prevent the possibility of a heavily ice up evaporating coil The appliance i...

Page 10: ...owever do not use the device in a sealed or very small space Operation 1 Turn the on off button also humidistat completely to OFF MIN mode the device is now deactivated Plug into a earthed mains socke...

Page 11: ...g its operation every 36 minutes and defrosting Compressor protection If you have turned off the device you cannot start it again during the first three minutes after that This is to protect the compr...

Page 12: ...how cracks or deformations Is the machine is stable and perfectly horizontal The unit is too noisy Check whether the unit is sitting on a level flat and solid surface Is the filter dusty contaminated...

Page 13: ...Ger t nach dem Transport oder Ankippen max 45 z B bei der Reinigung immer eine Stunde ruhen bevor Sie den Strom wieder anschlie en Sorgen Sie daf r dass die Lufteinlass und Luftauslass ffnungen stets...

Page 14: ...riker Bitten Sie immer um Originalersatzteile Dieses Ger t ist nicht geeignet um von Kindern oder von Personen bedient zu werden die eingeschr nkte physische sinnliche oder geistige F higkeiten zu wen...

Page 15: ...eines Verl ngerungskabels unvermeidlich so nehmen Sie eines mit Erdung und mit einem Mindestdurchmesser von 1 5 mm und rollen Sie das Kabel w hrend der Nutzung vollst ndig aus Das Ger t nicht in die...

Page 16: ...chlauch durch dem ffnung f r Kontinuierliche Ableitung nach unten in einen Abfluss oder gr eren Beh lter 5 Pr fen Sie ob das Wasser gut abl uft und der Schlauch an seiner Position bleibt Achtung Bei F...

Page 17: ...g Das Ger t funktioniert nicht Ist der Stecker eingesteckt Ist eine Sicherung durchgebrannt oder gibt es einen Stromausfall Liegt die Umgebungstemperatur zwischen 5 und 32 C Andernfalls arbeitet das G...

Page 18: ...l rt Euromac BV Genemuiden NL dass der Luftentfeuchter Marke EUROM Typ LO20 der Niedrig Energierichtlinie 2006 95 EG und der EMV Richtlinie 2004 108 EG entspricht und mit den unten stehenden Normen ko...

Page 19: ...sissez la fiche Ne tirez jamais sur le cordon Avant de brancher l appareil laissez le toujours au repos pendant une heure apr s un transport ou apr s que celui ci a t mis en position inclin e max 45 p...

Page 20: ...des pi ces d origine Cet appareil ne convient pas une utilisation par des personnes y compris des enfants souffrant d un handicap physique sensoriel ou mental ou manquant d exp rience ou de connaissan...

Page 21: ...l utilisation d une rallonge est in vitable utilisez une rallonge avec mise la terre et d une section minimale de 1 5 mm et d roulez enti rement le c ble pendant l utilisation Ne pas placer l apparei...

Page 22: ...le normalement et que le flexible reste bien en place Attention En cas de grand froid vous devez prot ger le flexible contre les risques de gel D congeler Lorsque l appareil fonctionne basse temp ratu...

Page 23: ...ctionne pas Le touche de MARCHE ARR T est elle en position MARCHE Le r servoir d eau est il plein est il correctement positionn Les entr es et sorties d air ne sont elles pas bloqu es L appareil sembl...

Page 24: ...directive CEM 2004 108 CE et qu il r pond aux normes suivantes EN 60335 1 2012 EN 60335 2 40 2003 A11 2004 A12 2005 A1 2006 A2 2009 A13 2012 EN 62233 2008 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 19...

Reviews: