30
Warning!
When you turn off the unit using only the remote control (or the app), the
'standby' remains. So turn it off using the remote control (c.q. the app) or the
on/off-switch and remove the plug from the socket!
Remove the batteries out of the season, that will extend the life of the remote
control.
When you use the appliance for the first time (or after a long time again),
observe it during the first 10 till 15 minutes to be sure that is works trouble-free.
Reset button
You can use the reset button in these situations:
-
To operate the device without the remote control. Every time that you press the
reset button (briefly), the output changes from: > 2000 W > 1320 W > 660 W >
off.
-
To reset the settings configured via the app to the factory settings. Hold down
the reset button for 4 seconds until the light comes on. Any previously set
password will then be reset to the factory setting password: 12345678. When the
shock safeguard has turned off the device, you can turn it on again in the same
way. (see: Schock safeguard).
APP control
The Eurom Heat and Beat can also be controlled by an app
that has been downloaded to a tablet or smart-phone (via
a Bluetooth connection). This app is available in the app
store for Apple devices and can be found under Eurom
heating. It is available for Android in the Google Play Store.
In order to be able to use the app, turn on the Bluetooth
connection on your smartphone or tablet and select Eurom
Heating.
With the app, you can:
-
Remotely switch the device on and off
-
Gradually adjust the heat from 0 to 100%
-
Set a timer that automatically switches the device off
-
Adjusting the speaker volume
-
Adjusting the colour and brightness of the LED lighting
-
Set the sensitivity of the shock safeguard
-
Set multiple heaters individually
-
Protect your app control with a password
Turning on the speakers and establishing the Bluetooth connection
Use the
button on the remote control to turn on the speakers
and Bluetooth connection for the Heat and Beat (hold down for 4 seconds). Before
using for the first time, select the volume function of the Heat and Beat (Eurom