The PM (Printer Module with database) is complement to the LUBE-Master monitoring system. With a PM connected
it is possible to have printouts of dispensed volume, see who made a dispense, type of fluid and on which JOB a
dispense was made.
NOTE! The LUBE-Master Installation guide should be available when installing and configuring a PM.
3. Mechanical installation
The PM is delivered mounted in a metal box.
Complete PM in a box is mounted on a wall or other suitable place using the four-ø5 mm holes in the bottom corners of
the box. The ticket printer (Eurolube part number 53354 or other Centronic parallel printer) should be placed protected
and secure not too far from the module. The printer cable is 2.5 meters.
If a small and compact system is needed the PCB version can be mounted in a MPDM. The chassis-connector on the
flat cable of the printer module is mounted in the “cut-out” hole on the side of the MPDM. See chapter 4.10.
4. Electric installation
The PM has two 4-pin connectors
(A)
marked
A
,
B
,
+24 V
and
Gnd
, which are used
for the
LUBE-Master
communication. Follow the cable recommendations in the LUBE-Master Installation guide. A PM normally gets its
power supply through the communication cable. If the module is placed far away from an MPDM it is possible to apply
an external power-supply to
one
of the connectors
(A)
.
NOTE! +24VDC may only be applied to one of the connectors.
203 02 63 C (From May 2018)
203 02 63B (To May 2018)
PM200 / 201
PM100 / 101
The RESET button
(B)
can be used to reset the module or reset the module address.
If the LED
(C)
flashes it indicates that the MPDM is working. If it is unlit or lit all the time something is wrong.
The short flat printer cable is connected to the parallel port connector marked
(D)
.
Use the two connectors
(E)
when installing a clock module, pn 53405.
DIL switches for termination and BIAS are marked
(F)
.
Communication driver
(G).
Processor speed crystal
(H).
PM200 / 201 = 25MHz. PM100 / 101 = 4MHz
OBSERVE! To be able to see and configure PM200 / PM201 from a LUBE-Master graphic layout LUBE-
Master R10 must be used. If an older LUBE-Master software version is used it can be updated by
replacing the Engine, adding PM200.ocx and PM201.ocx and then register the PM200.ocx by the
Windows “regsrv32.exe”.
A PM200 and PM201 will work in the system exactly as a PM100 or PM101 even without updating.