background image

PART NO 12740-41/12745-46 / ART.NR. 12740-41/12745-46

AiR OPeRATed sTAiNless sTeel PumP

www.eurolube.com

2

 

EUROLUBE EQUIPMENT 

205149

Manual 22770_EN_SE_1D 

3(11) 

1.

(EN) General

The air operated pump has two main parts. One double acting air motor driving a double acting liquid pump. 
The fluid is sucked into the pump through the bottom valve when the piston is on the upward stroke. The fluid is 
discharged in both up- and downs strokes. 
The relationship between then area of the air piston and area of the pump decides the pressure ratio. The pressure 
ratio is 4:1 and the theoretical pressure when the pump has stopped is 4 times higher than the air pressure. 
The exhaust air is blown out through a silencer made of sintered brass. 
All parts in contact with fluid are made of stainless steel (ISO 2346 and similar). The central bar is nickel plated. 
All packings in contact with fluid are manufactured of PTFE (Teflon). 

Important! Avoid operating the pump without fluid present, running the pump dry will damage the packings. 
For the same reason it is recommended to prime the pump with fluid before starting it. 

1.1. Safety precautions 

The pump is to be used with water based fluids like windscreen liquid, glycol/water mixture and non-
lubricant fluids like kerosene, white spirit, lacquer solvent and similar.
The pump may not be use for pumping petrol.

Check that all accessories and components are suitable for the distributed fluid and the working pressure of
the system.

The system must be tested to 1.3 times the working pressure before being put into operation.

Do not exceed the maximum air pressure of the pump, 1.0 MPa.

Close and disconnect the air supply and relieve the liquid pressure in the system before any work to the
pump or system is carried out

Only use genuine manufacturers spare parts. Never use worn or damaged spare parts.

Do not direct outlet valves or any other dispensing valve against the body or any other person as the liquid
can penetrate the skin or damage the eyes.

Always turn off the air pressure to the pump when the premises are unattended.

Technical data 

Tekniska data 

Pressure ratio 

4:1 

Tryckförhållande 

4:1 

Total length 

585mm/ 23” 

Totallängd 

585mm 

Pump tube length 

220mm/ 8.6” 

Pumprörslängd 

220mm 

Pump tube diameter 

Ø 54 mm/ 2.1”

Pumprörsdiameter 

Ø 54 mm

Air motor diameter 

Ø 80 mm/ 3.15”

Luftmotordiameter 

Ø 80 mm

Stroke length 

Approx. 100mm /4”

Slaglängd 

ca 100mm

Weight 

9.0kg/ 19.8 lbs

Vikt 

9.0kg

Max. air pressure 

1 Mpa/ 145 psi

Max. lufttryck 

1 Mpa

Min. air pressure 

0.4 Mpa/ 58 psi

Min. lufttryck 

0.4 Mpa

Max. fluid pressure 

4.0 Mpa/ 580 psi

Max. vätsketryck 

4.0 Mpa

Burst pressure 

Min. 10.0 Mpa/ 1450 psi

Sprängtryck 

Min. 10.0 Mpa

Free delivery (water at 0.7 

Mpa/100 psi air pressure) 

Approx. 30 l/min

Fritt avgivet vätskeflöde 
(vatten vid 0.7 Mpa 
lufttryck) 

ca. 30 l/min

Recommended max. 
delivery 

Approx. 20 l/min 

Rekommenderat max. flöde 

ca. 20 l/min 

Air connection 

BSP ¼” female/ G ¼” 

Luftanslutning 

G ¼” inv. 

Fluid outlet 

BSP 1” female/ G 1” 

Vätskeutlopp 

G 1” inv. 

Fluid inlet 

BSP 1” female/ G 1” 

Vätskeinlopp 

G 1” inv. 

Noice level at 0.7 Mpa/100 
psi 

84 dB 

Ljudnivå vid 0.7 Mpa 
lufttryck 

84 dB 

Drumadapter, 

111 72 77

 

Included 

Fatadapter, 

111 72 77

 

Ingår 

Suction tube, 

1

22 62 

9

4, 

required when mounting 

in drum 

Not included 

Sugrör, 

1

22 62 

9

4, för 

användning vid fatmontage 

Ingår ej 

Summary of Contents for 12740-41

Page 1: ...www eurolube com 1 205167 EUROLUBE EQUIPMENT PART NO 12740 41 12745 46 ART NR 12740 41 12745 46 Air operated stainless steel pump SERVICE GUIDE 2018 11 ORIGINAL MANUAL ...

Page 2: ...ng put into operation Do not exceed the maximum air pressure of the pump 1 0 MPa Close and disconnect the air supply and relieve the liquid pressure in the system before any work to the pump or system is carried out Only use genuine manufacturers spare parts Never use worn or damaged spare parts Do not direct outlet valves or any other dispensing valve against the body or any other person as the l...

Page 3: ...t of the drum or tank without difficulty Do not let the pump run fast when starting up a new system or after changing barrel in an existing system Start the pump with lowered air pressure on initial priming and gradually increase the pressure as the system is primed 3 EN Maintenance Empty and clean the air filter If a lubricator is installed it should always be filled with air tool oil or similar ...

Page 4: ...he bottom valve Pos 21 unscrew it for inspection If the bottom valve is removed the O ring Pos 22 must be replaced If the pump tube is removed from the outlet body the O ring Pos 16 must be replaced Do not over tighten the bottom valve or pump tube when reassembling The O rings will seal against leakage 5 EN Trouble shooting 5 1 Pump stationary or run very slowly 1 No or low air pressure 2 Faulty ...

Page 5: ...nd inte högre lufttryck än nödvändigt för att uppnå lämplig systemfunktion Kontrollera att alla anslutna komponenter är avsedda för den pumpade vätskan och lämpade för systemets arbetstryck Provtryck alla rörledningar med 1 3 x systemets arbetstryck innan det tas i drift Stäng av eller koppla bort trycklufttillförseln och avlasta systemet innan något arbete på pump eller system påbörjas Använd ell...

Page 6: ...ar och tätningar smörjas före återmontering Använd helst varnolen eller liknande vätska vid rengöring av delar till luftmotorn 9 1 Luftmotor Fäst pumpens utloppshus i ett skruvstycke med pumpröret nedåt Lossa de fyra skruvarna i locket och ta bort det Luftanslutningsnippeln Pos 2 sitter fast i växlingsmekanismen med två O ringar För att ta bort luftfiltret Pos 3 gängar man försiktigt ned en M6 skr...

Page 7: ...emonteras ska O ringen Pos 16 bytas 10 SE Felsökning 10 1 Pumpen går ej 1 Ingen eller låg lufttillförsel 2 Sliten eller skadad luftmotor 10 1 1 Åtgärd 1 Kontrollera luftledningens ventil regulator och snabbkoppling 2 Se service luftmotor 10 2 Pumpen går ojämnt och hackar 1 Is i ljuddämparen 10 2 1 Åtgärd 1 Töm luftledningens vattenavskiljare på kondensat och vänta några minuter före återstart så i...

Page 8: ...1 1 142 52 67 Air inlet kit Air inlet adapter O ring Air filter Luftanslutningssats Anslutningsnippel O ring Luftfilter 2 2 3 1 2 1 142 52 68 Repair kit mechanism Renoveringssats mekansim 24 1 142 52 69 Central bar kit O ring Central bar Clamping pin Centralstångssats O ring Centralstång Rörpinne 6 15 17 1 1 1 102 89 80 Protective cover Skyddsplåt 27 1 142 61 78 Packing kit liquid part Box packing...

Page 9: ...www eurolube com 9 205167 EUROLUBE EQUIPMENT PART NO 12740 41 12745 46 ART NR 12740 41 12745 46 Air operated stainless steel pump Manual 22770_EN_SE_1D 10 11 ...

Page 10: ...gen 4 138 40 Älta Sweden declares hereby that the products 12740 41 12745 46 are in conformity with the requirements of the Council s Machinery Direc tive 2006 42 EC Älta April 17 2015 Alentec Orion AB Grustagsvägen 4 138 40 Älta deklarerar härmed att produkterna 12740 41 12745 46 är tillverkade i överensstämmelse med bestämmelserna i Maskindirektivet 2006 42 EC Älta April 17 2015 Krister Tynhage ...

Reviews: