CONTINOUS OPERATION
Press the
VOLUME
button, to activate continuous fog output. The display indicates “
Volume
“ followed by the
value that was set in menu item “
Volume Out
”. To stop the fog output, press the
VOLUME
button once again.
MANUAL OPERATION
For immediate fog output at the maximum volume of fog, keep the
MANUAL
button pressed. The display
indicates “
Manual Output
“. As soon as you release the button, the fog output will stop. The manual operation will
take priority over the continuous operation and the timer operation. Even if one of these operating modes is
activated, the fog machine will always emit the maximum volume of fog when the
MANUAL
button is pressed.
WIRELESS REMOTE CONTROL
1
Put the receiving antenna in a vertical position on the machine.
2
Press the
left
button on the remote control to emit fog (continuous
operation with 100 % fog volume). The
control LED
between the two
buttons lights up.
3
To stop the fog output, press the
right
button.
4
If necessary, the wireless remote control can be turned off in the menu
(
option Wireless
). If it’s activated, a “
W
“ for wireless is indicated in the
display.
5
If the remote control is not working properly, it must be assigned to the
unit. The remote control can be assigned during a short period of time
after switching on the machine as long as the display shows the
following indication:
To assign the remote control, press and hold one of the buttons until
the display flashes repeatedly, to indicate a match. This can take up to
12 seconds. Thus, the remote control has been assigned to the
machine and may be used for wireless control.
FLUID SENSOR
1
When the tank runs out during use, the fluid pump is switched off automatically for protection purposes and
“
No Fluid
” is shown on the display.
2
Disconnect the fog machine from the power supply before changing the tank or filling it with fog fluid. Then,
keep pressing the
MANUAL
button in order to completely fill the fluid hose with fog fluid again, in order to
prevent the automatic pump switch-off from reactivating. Then the display shows "
Ready To Fog
" and the unit
is ready to emit fog again.
3
The fluid sensor control can be turned off in the menu (option
Fluid Sensor
). However, it is a very important
protection mechanism and should remain activated for proper operation. If its activated, an “
S
“ for fluid sensor
is indicated in the display.
NOTES REGARDING OPERATION
1
During operation fog emission may stop. In this case the device is heating up again. After a short period, the
machine will be ready to emit fog again. This process guarantees an appropriate vaporization temperature
and the best fog emission possible. The temperature is regulated by a high-quality thermostat.
2
All fog machines may sputter small amounts of fog occasionally during operation and for a minute or so after
being turned off.
3
If you experience low output, pump noise or no output at all, disconnect from mains immediately. Check the
fluid level, the thermal safety switch and the power supply. If all of the above appears to be ok, reconnect the
unit again. If fog does not come out after holding the
MANUAL
button for 30 seconds, check the tube
attached to the tank to make sure there is fluid going through it. If you are unable to determine the cause of
the problem, do not simply continue pushing the operating button, as this may damage the unit. Return the