00081193, Version 1.0
32/39
Slave setting
With this function, you can define the device as slave.
• Select
“SLAV”
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
, the display shows
“ON”
or
“OFF”
.
• Press
[UP]
to select
“ON”
if you wish to enable this function or
[DN]
to select
“OFF”
if you don’t.
• Press
[ENTER]
to confirm.
• Press
[MODE/ESC]
in order to return to the main menu.
Program Run, Master setting
With this function, you can run the internal program.
• Select
"SEQU"
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
, the display shows
“ALON”
or
“MAST”
. The selection "ALON" means stand-alone
mode and "MAST" that the device is defined as master.
• Select
"ALON"
or
"MAST"
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
to confirm.
• Press
[MODE/ESC]
in order to return to the main menu.
Music, Master setting
With this function, you can run the internal program sound-controlled.
• Select
"SUND"
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
, the display shows
“ALON”
or
“MAST”
. The selection "ALON" means stand-alone
mode and "MAST" that the device is defined as master.
• Select
"ALON"
or
"MAST"
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
to confirm.
• Press
[MODE/ESC]
in order to return to the main menu.
LAMP
• Press
[MODE/ESC]
to enter the main menu
“LAMP"
(display flashing)
• Press
[ENTER]
and select
“TEMP
“ or
“ADJU“
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
for selecting the desired sub menu.
Max. Temperature
With this function you can set the inside temperature at which the projector will automatically switch
the lamp/LEDs off. Inside temperatures below 90 °C are not critical. 90 °C and more should lead to
the lamp/LEDs being switched off. Please note that the outside temperature should not exceed 45
°C.
• Select
"TEMP"
, to select the maximum inside temperature between 80 °C and 139 °C, by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
to confirm, the display shows
“90°C "
.
• Press
[UP]
or
[DN]
to select
"80-139°C "
for the desired inside temperature.
• Press
[ENTER]
to confirm.
• Press
[MODE/ESC]
in order to return to the main menu.
INFO
• Press
[MODE/ESC]
to enter the main menu
“INFO"
(display flashing)
• Press
[ENTER]
and select
“DRIT“
by pressing
[UP]
or
[DN]
.
Temperature near LED driver
With this function you can display the temperature in the projector-head (near LED driver) in degree
Celsius.
• Select
“DRIT”
by pressing
[UP]
or
[DN]
.
• Press
[ENTER]
, the display shows
“XXXC”
, “X“ stands for the temperature.
• Press
[ENTER]
to confirm.
• Press
[MODE/ESC]
in order to return to the main menu.