EuroLite LED Pixel Panel 16 DMX User Manual Download Page 7

 

00049912.DOC, Version 1.4 

20/28

Overhead rigging 

 

DANGER TO LIFE! 

 

Please consider the EN 60598-2-17and the respective national standards during the installation!  

 

The installation must only be carried out by an authorized dealer! 

 

The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 
1 hour without any harming deformation. 

 

The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. 
This secondary safety attachment must be constructed in a way that no part of the installation can fall down 
if the main attachment fails. 

 

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, 
under high working places and other endangered areas is forbidden. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert before taking into operation for the first time and after changes before taking into operation another 
time. 

 

The operator has to make sure that safety-relating and machine-technical installations are approved by an 
expert after every four year in the course of an acceptance test. 

 

The  operator  has  to  make  sure  that  safety-relating  and  machine-technical  installations  are  approved  by  a 
skilled person once a year. 

 

Procedure: 

The device should be installed outside areas where persons may walk by or be seated. 

 

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) 
calculating  working  load  limits,  installation  material  being  used,  and  periodic  safety  inspection  of  all 
installation material and the device. If you lack these qualifications, do not attempt the installation yourself, 
but  instead  use  a  professional  structural  rigger.  Improper  installation  can  result  in  bodily  injury  and.or 
damage to property. 

 

The device has to be installed out of the reach of people. 

 

If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used. 
The device must never be fixed swinging freely in the room. 

 

Caution:

 Devices may cause severe injuries when crashing down! If you have doubts concerning the safety 

of a possible installation, do NOT install the device! 

 

Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's 
weight. 

 

DANGER OF FIRE!

When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.

 

 

Mount the device with both mounting-brackets to your trussing system using appropriate clamps. 

 

For overhead use, always install an appropriate safety bond. 

 

You must only use safety bonds and quick links complying with DIN 56927, shackles complying with DIN EN 
1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the carbines must be sufficiently 
dimensioned  and  used  correctly  in  accordance  with  the  latest  industrial  safety  regulations  (e.  g.  BGV  C1, 
BGI 810-3). 
 

Please  note:

  for  overhead  rigging  in  public  or  industrial  areas,  a  series  of  safety  instructions  have  to  be 

followed  that  this  manual  can  only  give  in  part.  The  operator  must  therefore  inform  himself  on  the  current 
safety instructions and consider them. 

 

The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety 
precautions! 

 

Lead  the  safety  bond  through  the  mounting-bracket  of  the  device  and  over  the  trussing  system  or  a  safe 
fixation spot. Insert the end in the quick link and tighten the safety screw. 

 

Summary of Contents for LED Pixel Panel 16 DMX

Page 1: ... Copyright Nachdruck verboten Reproduction prohibited Für weiteren Gebrauch aufbewahren Keep this manual for future needs BEDIENUNGSANLEITUNG USER MANUAL LED Pixel Panel 16 DMX ...

Page 2: ... SAFETY INSTRUCTIONS 16 OPERATING DETERMINATIONS 17 DESCRIPTION OF THE DEVICE 18 RIGGING 19 Overhead rigging 20 Fixed Installation 21 DMX512 connection connection between fixtures 21 Master Slave operation 22 Connection with the mains 22 Connection between devices 23 OPERATION 23 OPERATION VIA DIP SWITCHES 23 Auto Mode 23 Internal Programs Mode 23 Sound Control 23 Blackout 24 DMX CONTROLLED OPERAT...

Page 3: ...nel 16 DMX SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in th...

Page 4: ...evice is dusty the device must be taken out of operation disconnected and then be cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extension cords or any holes in the housing of the device If you suppose that also a minim...

Page 5: ...ed with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Make sure that you pack the device in the original state Please consider ...

Page 6: ...1 2 4 8 16 32 64 128 256 Address DIP Function 3 4 5 6 7 8 8 Overview Front 1 Fixation screws of the cover plate 2 Individually controlable tricolor LEDs 3 DMX OUT 4 Power OUT 5 DMX IN 6 Power IN 7 DIP switches 8 Mounting brackets for fixed installation or mounting on a trussing system RIGGING Fixed installation or mounting on a trussing system possible Note This device is designed for vertical con...

Page 7: ... these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freel...

Page 8: ...y the fixing material must be chosen to suit the wall material Always ask a specialist for the correct plug screw combination indicating the maximum load and the building material Procedure Step 1 Unscrew the four fixation screws in the corners on the front of the cover plate and remove them with the cover plate Step 2 In the device you will see four 20mm holes for installation which go through to...

Page 9: ... and a 3 pin XLR plug for DMX output which can be used for connecting several devices Choose the device which is to control the effects This device then works as master device and controls all other slave devices which are to be connected to the master device via a DMX cable Connect the OUT jack with the IN plug of the next device Set DIP Switch 10 to 0 in order to determine the Master device then...

Page 10: ... via Dip1 Dip5 Speed via Dip6 Dip8 Sound controlled color change See DMX Protocol Black Out 1 DMX address is 1 in DMX Mode 2 Slave device in M S Modus Mode Dip 1 Dip 2 Dip 3 Dip 4 Dip 5 Dip 6 Dip 7 Dip 8 Dip 9 Dip 10 0 0 X X X X X X X X 22 Internal Sound control DMX X 0 0 0 0 0 X X 1 0 X X X X X X X X X X X X X X X 1 1 0 1 X 1 0 0 0 0 0 0 0 Programs Master 0 0 0 0 0 0 0 0 1 0 Other 0 0 Auto Master...

Page 11: ... 0 0 0 1 1 0 1 1 1 0 0 0 1 1 0 0 0 1 0 Red green red green Red blue red blue Green green violet violet Red red blue blue White off white off Red off red off Red red blue blue Green green violet violet 7 Color flow in the opposite direction 7 Color flow in both directions 7 Color Chaser in one direction 7 Color Chaser in the opposite direction Dip 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 DMX C...

Page 12: ...fixture on the DMX data link If two three or more devices are addressed similarly they will work similarly Controlling After having addressed all LED Pixel Panels you may now start operating these via your lighting controller The LEDs of the device are separated into 16 pixels on the main panel see graphic which can be individually controlled with the following DMX protocol Depending upon the inst...

Page 13: ...G7 CH 21 B7 CH 22 R8 CH 23 G8 CH 24 B8 CH 25 R9 CH 26 G9 CH 27 B9 CH 28 R10 CH 29 G10 CH 30 B10 CH 31 R11 CH 32 G11 CH 33 B11 CH 34 R12 CH 35 G12 CH 36 B12 CH 37 R13 CH 38 G13 CH 39 B13 CH 40 R14 CH 41 G14 CH 42 B14 CH 43 R15 CH 44 G15 CH 45 B15 CH 46 R16 CH 47 G16 CH 48 B16 ...

Page 14: ...by a special power supply cable available at your dealer Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 90 240 V 50 60 Hz Power consumption 17 W Number of DMX channels 48 DMX 512 connection 3 pin XLR Sound control via built in microphone Maximum ambient temperature Ta 45 C Maximum housing temperature TC steady state 50 C Min distance from flammab...

Page 15: ...X IN LIGHTING CONTROL PROTOCOL DMX512 XLR occupation 1 Ground 2 Signal 3 Signal POWER OUT 230V AC 50Hz DMX OUT DMX ADDRESS 1 2 3 4 5 6 7 8 9 10 1 2 4 8 16 32 64 128 256 Address DIP Function Please note All information is subject to change without prior notice 15 10 2015 ...

Reviews: