00049912.DOC, Version 1.4
19/28
1
2
3
4
5
6
POWER IN:
230V AC,50Hz~
DMX IN
LIGHTING CONTROL
PROTOCOL DMX512
XLR occupation:
1: Ground
2: Signal (-)
3: Signal (+)
POWER OUT:
230V AC,50Hz~
DMX OUT
DMX ADDRESS
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128 256
Address
DIP
Function
3
4
5
6
7
8
8
Overview
Front
1. Fixation screws of the cover plate
2. Individually controlable tricolor LEDs
3. DMX OUT
4. Power OUT
5. DMX IN
6. Power IN
7. DIP-switches
8. Mounting brackets for fixed installation or mounting on a trussing system
RIGGING
Fixed installation or mounting on a trussing system possible.
Note:
This device is designed for vertical connections.
Rear