This device falls under protection-class I. The power plug must only be plugged into a protection class I 
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or 
power outlets can lead to the destruction of the device and to mortal electrical shock. 

 

Always plug in the power plug last. The power plug must always be inserted without force. Make sure that 
the plug is tightly connected with the outlet. 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all connections 
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal 
electrical shock. 

 

Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next 
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock. 

 

The cable insert or the female part in the device must never be strained. There must always be sufficient 
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage. 

 

Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the 
power-cord from time to time. 

 

If extension cords are used, make sure that the core diameter is sufficient for the required power 
consumption of the device. All warnings concerning the power cords are also valid for possible extension 
cords. 

 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the 
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can 
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the 
device must be disconnected via the mains. 

 

If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be 
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More 
severe dirt in and at the device should only be removed by a specialist. 

 

There must never enter any liquid into power outlets, extension cords or any holes in the housing of the 
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately 
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still 
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced 
insulation can cause mortal electrical shock. 

 

There must never be any objects entering into the device. This is especially valid for metal parts. If any metal 
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and 
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries. 

 

HEALTH HAZARD!

Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!

 

 

Keep away children and amateurs! 

 

Never leave this device running unattended. 
 

OPERATING DETERMINATIONS 

This device is a LED moving-head lighting effect for creating decorative effects. This product is allowed to be 
operated with an alternating current of 100-240 V, 50/60 Hz and was designed for indoor use only. 

 

This device is designed for professional use, e.g. on stages, in discotheques etc. 

 

Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Never lift the fixture by holding it at the projector-head, as the mechanics may be damaged.  

 

When choosing the installation-spot, please make sure that the device is not exposed to extreme heat, 
moisture or dust. There should not be any cables lying around. Please make sure that the unit cannot be 
touched or bumped. You endanger your own and the safety of others! 

 

Summary of Contents for LED MFX-9

Page 1: ......

Page 2: ...UCTION 24 SAFETY INSTRUCTIONS 24 OPERATING DETERMINATIONS 25 DESCRIPTION OF THE DEVICE 27 Features 27 Overview 27 INSTALLATION 28 Rigging 28 DMX512 control 30 Master Slave operation 31 Connection with...

Page 3: ...ter laden EINF HRUNG Wir freuen uns dass Sie sich f r einen EUROLITE LED MFX 9 Strahleneffekt entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ih...

Page 4: ...rungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzleitung gelten auch f r evtl Verl n...

Page 5: ...ntfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie da...

Page 6: ...Ihren H ndler oder die zust ndige rtliche Beh rde GER TEBESCHREIBUNG Features LED Strahlen Pyramide mit endloser PAN Bewegung Ausgestattet mit neun 8 W Quadcolor LEDs mit RGBW Farben DMX gesteuerter B...

Page 7: ...Board mit Bedientasten 4 DMX Eingang 5 DMX Ausgang 6 Spannungsversorgungseingang 7 Netzschalter 8 Sicherungshalter 9 Gummif e 10 L fter MIC UP DOWN ENTER MODE LED MFX 9 BEAM EFFECT 1 2 3 DMX OUT 1 Gro...

Page 8: ...reiches von Personen installiert werden WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MA AN ERFAHRUNG Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit v...

Page 9: ...hen und diese einhalten Der Hersteller haftet nicht f r Sch den die durch unsachgem e Installation und unzureichende Sicher heitsvorkehrungen verursacht werden H ngen Sie das Schnellverschlussglied d...

Page 10: ...g zwischen Controller und Ger t sowie zwischen den einzelnen Ger ten sollte mit einem DMX Kabel erfolgen Die Steckverbindung geht ber 3 polige XLR Stecker und Kupplungen Belegung der XLR Verbindung We...

Page 11: ...geschlossen werden Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installa...

Page 12: ...512 DMX512 22CH xxx 001 DMX512 13CH xxx 001 DMX512 11CH xxx 001 DMX512 8CH xxx 001 DMX512 5CH xxx 001 MENU 2 TEST Master Modus TEST CH01 xxx 000 T CH49 xxx 000 Testfunktion der entsprechenden Kan le C...

Page 13: ...Kette funktioniert Werden mehrere LED MFX 9 Strahleneffekte auf eine Adresse definiert arbeiten sie synchron Dr cken Sie die Up Down Tasten um die gew nschte Startadresse einzustellen Nun k nnen Sie...

Page 14: ...y 000 001 Keine Funktion 002 128 Im Uhrzeigersinn mit zunehmender Geschwindigkeit 129 255 Gegen den Uhrzeigersinn mit zunehmender Geschwindigkeit 3 Rot 000 255 Zunehmende Intensit t 0 100 4 Gr n 000 2...

Page 15: ...45 Programm 8 246 255 Programm 9 8 Reset 000 250 Keine Funktion 251 255 Reset 11 Kanal Modus Kanal Wert Funktion 1 PAN Bewegung 000 255 Innerhalb 0 540 2 PAN Infinity 000 001 Keine Funktion 002 128 Im...

Page 16: ...rogramm 2 204 210 Programm 3 211 217 Programm 4 218 224 Programm 5 225 231 Programm 6 232 238 Programm 7 239 245 Programm 8 246 255 Programm 9 Horizontale Ebenen CH4 1 CH5 2 CH6 3 Vertikale Leisten CH...

Page 17: ...m 6 043 049 Programm 7 050 056 Programm 8 057 063 Programm 9 Standalone ohne PAN Bewegung 064 070 Programm 1 071 077 Programm 2 078 084 Programm 3 085 091 Programm 4 092 098 Programm 5 099 105 Program...

Page 18: ...1 PAN Bewegung 000 255 Innerhalb 0 540 2 PAN Bewegung mit 16 Bit Aufl sung 000 255 Feinindizierung 3 Geschwindigkeit PAN Bewegung 000 255 Abnehmende Geschwindigkeit 4 PAN Infinity 000 001 Keine Funkt...

Page 19: ...225 231 Programm 6 232 238 Programm 7 239 245 Programm 8 246 255 Programm 9 12 Geschwindigkeit interne Programme 000 255 Zunehmende Geschwindigkeit CH13 LED 1 CH14 LED 2 CH15 LED 3 CH16 LED 4 CH17 LED...

Page 20: ...au 000 255 Zunehmende Intensit t 0 100 9 Wei 000 255 Zunehmende Intensit t 0 100 10 Strobe 000 000 Keine Funktion 001 255 Zunehmende Geschwindigkeit 11 Interne Programme Standalone mit PAN Bewegung 00...

Page 21: ...rogramm 2 204 210 Programm 3 211 217 Programm 4 218 224 Programm 5 225 231 Programm 6 232 238 Programm 7 239 245 Programm 8 246 255 Programm 9 12 Geschwindigkeit interne Programme 000 255 Zunehmende G...

Page 22: ...elm ig von Verunreinigungen wie Staub usw gereinigt werden Verwenden Sie zur Reinigung ein fusselfreies angefeuchtetes Tuch Auf keinen Fall Alkohol oder irgendwelche L sungsmittel zur Reinigung verwen...

Page 23: ...ung PAN unbegrenzt Ma e LxBxH 360x320x315 mm Gewicht 7 kg Zubeh r Best Nr EUROLITE TPC 10 Klammer silber 59006856 EUROLITE TPC 10 Klammer schwarz 59006858 EUROLITE Sicherungsseil A 4x1000mm bis 15kg s...

Page 24: ...SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely...

Page 25: ...cleaned with a dry cloth Dust can reduce the insulation which may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter an...

Page 26: ...sing must never touch surrounding surfaces or objects Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture For overhead use mounting height 1...

Page 27: ...ed individually Sound controlled via built in microphone Microphone sensitivity adjustable via control board Fan cooled Narrow illumination angle Addressing and setting via control board with LCD Func...

Page 28: ...into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an...

Page 29: ...DIN 56927 shackles complying with DIN EN 1677 1 and BGV C1 carbines The safety bonds quick links shackles and the carbines must be sufficiently dimensioned and used correctly in accordance with the la...

Page 30: ...DMX 512 Controller 120 Ohms DMX OUT 1 Ground 2 Signal 3 Signal DMX IN 100 240 V AC 50 60 Hz POWER IN ON OFF FUSE T2A 250V DMX OUT 1 Ground 2 Signal 3 Signal DMX IN 100 240 V AC 50 60 Hz POWER IN ON OF...

Page 31: ...nal program or the test function for the master device as described in chapter Control Board Set the DMX address 001 for all slave devices Please see further instructions under Control Board Connectio...

Page 32: ...X channel mode 49CH 22CH 13 CH 11CH 8CH or 5CH and DMX starting address 001 512 DMX512 22CH xxx 001 DMX512 13CH xxx 001 DMX512 11CH xxx 001 DMX512 8CH xxx 001 DMX512 5CH xxx 001 MENU2 TEST Master Mode...

Page 33: ...eral LED MFX 9 Beam Effects are addressed similarly they will work synchronically Press the Up Down buttons for setting the desired starting address Now you can start operating the LED MFX 9 Beam Effe...

Page 34: ...inity 000 001 No function 002 128 Clockwise with increasing speed 129 255 Counterclockwise with increasing speed 3 Red 000 255 Increasing intensity 0 100 4 Green 000 255 Increasing intensity 0 100 5 B...

Page 35: ...5 Program 8 246 255 Program 9 8 Reset 000 250 No function 251 255 Reset 11 Channel Mode Channel Value Function 1 PAN Movement 000 255 Within 0 540 2 PAN Infinity 000 001 No function 002 128 Clockwise...

Page 36: ...204 210 Program 3 211 217 Program 4 218 224 Program 5 225 231 Program 6 232 238 Program 7 239 245 Program 8 246 255 Program 9 Horizontal Levels CH4 1 CH5 2 CH6 3 Vertical Strips CH7 1 CH8 2 CH9 3 000...

Page 37: ...49 Program 7 050 056 Program 8 057 063 Program 9 Stand alone without PAN movement 064 070 Program 1 071 077 Program 2 078 084 Program 3 085 091 Program 4 092 098 Program 5 099 105 Program 6 106 112 Pr...

Page 38: ...et 22 Channel Mode Channel Value Function 1 PAN Movement 000 255 Within 0 540 2 PAN Movement with 16 Bit resolution 000 255 Fine indexing 3 Speed PAN Movement 000 255 Decreasing speed 4 PAN Infinity 0...

Page 39: ...ram 5 225 231 Program 6 232 238 Program 7 239 245 Program 8 246 255 Program 9 12 Speed internal Programs 000 255 Increasing speed CH13 LED 1 CH14 LED 2 CH15 LED 3 CH16 LED 4 CH17 LED 5 CH18 LED 6 CH19...

Page 40: ...creasing intensity 0 100 9 White 000 255 Increasing intensity 0 100 10 Strobe 000 000 No function 001 255 Increasing speed 11 Internal programs Stand alone with PAN movement 000 000 No function availa...

Page 41: ...1 197 203 Program 2 204 210 Program 3 211 217 Program 4 218 224 Program 5 225 231 Program 6 232 238 Program 7 239 245 Program 8 246 255 Program 9 12 Speed of internal Programs 000 255 Increasing speed...

Page 42: ...d installer and any safety problems have to be removed Disconnect from mains before starting maintenance operation DANGER TO LIFE We recommend a frequent cleaning of the device Please use a moist lint...

Page 43: ...ment unlimited Dimensions LxWxH 360x320x315 mm Weight 7 kg Accessories No EUROLITE TPC 10 Coupler silver 59006856 EUROLITE TPC 10 Coupler black 59006858 EUROLITE Safety bond A 4x1000mm up to 15kg silv...

Page 44: ...Eurolite is a brand of Steinigke Showtechnic GmbH Andreas Bauer Str 5 97297 Waldb ttelbrunn Germany D00103748 doc Version 1 0 Publ 29 11 2016...

Reviews: