background image

20 

 

Cleaning 

Cleaning schedules for lighting fixtures vary greatly depending on the operating 
environment. Environmental factors that may result in a

 

need for frequent cleaning include:

 

 

Use of smoke or fog machines.

 

 

High airflow rates (near air conditioning vents, for example).

 

 

Presence of cigarette smoke.

 

 

Airborne dust (from stage effects, building structures and fittings or the natural 

environment at outdoor events, for example).

 

If one or more of these factors is present, inspect fixtures within their first 100 hours of 
operation to see whether cleaning is necessary. Check again at frequent intervals. This 
procedure will allow you to assess cleaning requirements in your particular situation. If 
have any question,please contact dealer.

 

Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any 
product that contains solvents or abrasives, as these can cause surface damage.

 

Warning! Disconnect from power and allow to cool before cleaning.

 

To clean the fixture:

 

1.

 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

 

2.

 

Vacuum or gently blow away dust and loose particles from the outside of the 

fixture and the air vents at

 

the back and sides of the head and in the base with low-pressure compressed air.

 

3.

 

Please use the professional cloth to clean the optical lens and soak with low 

concentration detergent liquid.

 

Do not rub the surface hard: lift particles off with a soft repeated press. Dry with a 
soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles 
with an unscented tissue or cotton swab moistened with glass cleaner or distilled 
water.

 

4.

 

Check that the fixture is dry before reapplying power.

 

Specifications subject to change without notice.

 

If have questions,please contact the dealer.

 

Summary of Contents for HL-BSW380

Page 1: ...HL BSW380 380W Beam Spot Wash 3in1 Moving Head Light User manual Thanks for choosing our goods please read this manual carefully before your operating ...

Page 2: ... Contents Introduction 3 Dimensions 4 Safety Information 5 Using for the first time 7 AC power 8 Data link 8 Setup 9 Menu chart 10 DMX Protocol Channel Function 14 Service and maintenance 19 Cleaning 20 ...

Page 3: ...ally rotatable and gobo shaking at variable speeds Prism 8 6facet circular prism 10 20 zooming Dimmer 0 100 linear dimmer Strobe 0 3 20times second double lens strobe with adjustable speed Pan and Tilt Smoothly automatic Pan Tilt position correction speed adjustable Range Pan540 Tilt 280 Frost 8 60 washing Effect Color Gobo Prism Strobe automatic operation function Cooling Fan Cooling Control mode...

Page 4: ...4 Dimensions ...

Page 5: ...rface protective manual injury or death of lethal or With risk of Do not touch Eye wear severe electric burned eyes shock Warning High brightness light source don t look at the light directly so that keep the risk of burned eyes away This product is for professional use only It is not for household use This product presents risks of severe injury or death due to fire and burn hazards electric shoc...

Page 6: ...nectors to connect to power throughput sockets Isolate the fixture from power immediately if the power plug or any seal cover cable or other Component is damaged defective deformed wet or showing signs of overheating Do not reapply power until repairs have been completed Do not expose the fixture to rain or moisture PROTECTION FROM BURNS AND FIRE Do not operate the fixture if the ambient temperatu...

Page 7: ...nstalling servicing or moving the fixture Do not operate the fixture with missing or damaged covers shields or any optical component Using for the first time Important After unpacking please check the goods damage or not which due to the transportation If you find damage please do not use this item then contact the dealer or manufacturer as soon as possible Please read the Safety Information befor...

Page 8: ...z Do not apply AC mains power to the fixture at any other voltage than that specified on the fixture s serial number label Data link A DMX 512 data link is required in order to control a 350BSW via DMX This light has 5 pin XLR connectors for DMX data input and output The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Pins 4 and 5 in the 5 pin XLR connectors are not used in this...

Page 9: ...ink with a 120 Ohm resistor When this light turned on the display screen and key button get flash in every second once the fixture without the DMX signal When insert DMX signal the display screen and key button stop flashing it stand for run into the DMX control mode 20 seconds later the display will be in power save mode and the the key button indicator turn off Setup Control panel and menu navig...

Page 10: ...Remark Language 中 EN Setting Run Mode DMX Sound Random DMX Address 001 512 Channel Mode Std 19CH Ext 24CH Sound Regulator 003 003 Invert Pan ON OFF Invert Tilt ON OFF Pan Tilt Encoder ON OFF NO DMX Signal KEEP CLEA Display ON OFF Lamp On Startup ON OFF ScreenAutoRotation ON OFF Load Default OK CANCEL ...

Page 11: ... Gobo Rotation 000 255 12 Gobo1RtFine 000 255 13 Prism 000 255 14 Prism Rotation 000 255 15 Prism1 000 255 16 Prism1 Rotation 000 255 17 Frost 000 255 18 Zoom 000 255 19 ZoomFine 000 255 20 Focus 000 255 21 FocusFine 000 255 22 Shutter Strobe 000 255 23 Dimmer 000 255 24 Dimmer Fine 000 255 Info Ver 350 A011 DMX Monitor System Errors Total Fixture Hours 00000 00 Partial Fixture Hours 00000 00 Tota...

Page 12: ...ast to slow Channel 4 Channel 6 Power Special functions 0 19 Reserved 20 24 Half Power 25 29 Full Power 30 69 Reserved 70 79 Pan Tilt Rotate Off Light 80 89 Pan Tilt Rotate On Light 90 129 Reserved 130 139 Lamp on 140 149 Pan Tilt Reset 150 189 Effect Reset 190 199 Reserved 200 209 Full Reset 210 229 Reserved 230 239 Lamp Off 240 255 Reserved Channel 5 Channel 7 Macro Color 0 127 Linear Color Open...

Page 13: ...7 GOBO4 28 33 GOBO5 34 39 GOBO6 40 45 GOBO7 46 51 GOBO8 52 57 GOBO9 58 63 GOBO10 64 69 GOBO 11 70 75 GOBO12 76 81 GOBO13 82 87 GOBO14 88 95 96 103 GOBO1 Shake Slow Fast GOBO2 Shake Slow Fast 104 111 GOBO3 Shake Slow Fast 112 119 GOBO4 Shake Slow Fast 1 20 1 27 GOBO5 Shake Slow Fast 128 135 GOBO6 Shake Slow Fast 136 143 GOBO7 Shake Slow Fast 144 151 GOBO8 Shake Slow Fast 152 159 GOBO9 Shake Slow Fa...

Page 14: ...O2 3 Shake Slow to Fast 65 72 GOBO2 4 Shake Slow to Fast 73 80 GOBO2 5 Shake Slow to Fast 81 88 GOBO2 6 Shake Slow to Fast 89 96 GOBO2 7 Shake Slow to Fast 97 104 GOBO2 8 Shake Slow to Fast 105 112 GOBO2 9 Shake Slow to Fast 113 119 Big White 120 185 Fast Rotation Slow Rotation 186 189 Stop 190 255 Slow Rotation Fast Rotation Channel 8 Channel 11 Rot gobo indexing and rotation 0 127 Rotation index...

Page 15: ...tion Slow Rotation Channel 13 Channel 17 Frost 0 64 Reserved 65 255 Linear Frost Channel 14 Channel 18 Zoom 0 255 Linear Zoom Channel 19 0 255 Zoom Fine Channel 15 Channel 20 0 255 Focus Channel 21 0 255 Focus Fine Channel 16 Channel 22 Shutter 0 31 Close Shutter 32 63 Open Shutter 64 95 Slow to Fast 96 127 Open Shutter 128 143 Fast Strobe Slow Strobe 144 159 Slow Strobe Fast Strobe 160 191 Open S...

Page 16: ...tenance is not covered by the product warranty Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED to see if it can be light up or not B Not responding to DMX...

Page 17: ... a clean well lit area Do not use any product that contains solvents or abrasives as these can cause surface damage Warning Disconnect from power and allow to cool before cleaning To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture and the air vents at the back an...

Reviews: