00107903.DOC, Version 1.1
26/36
OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board and the EUROLITE IR-7 remote control or in DMX-controlled mode via any
commercial DMX controller.
Operating buttons
Button
Function
MENU
Selects the operating mode or returns to the initial screen.
ENTER
Activates a value to be modified or saves a value when modifying.
UP
Selects the next menu item or increases values when modifying.
DOWN
Selects the previous menu item or decreases values when modifying.
Menu structure
Mode
Display
Function
DMX mode
Addr
23CH
d001-490
23-channel mode and start address
7CH
d001-506
7-channel mode and start address
4CH
d001-509
4-channel mode and start address
Slave mode
SLAV
SLAU
Slave mode
Preset colors
Cxx
C01 – C15
Constant lighting in one of 15 colors
*
Automatic mode
Auto
Au01 – Au03
Automatic programs
Sound control
Soun
So01 – So03
Sound-controlled programs
Running speed in
automatic and sound-
controlled mode
SPEE
SP01 – SP09
Program running speed slow > fast
Microphone sensitivity
for sound control
SEnS
SE01 – SE09
Microphone sensitivity
low > high
Sound control
„silent scene“
SILE
on
LEDs off if there is no music signal
oFF
LEDs remain on if there is no music signal
IR remote control
InFr
on
IR remote control on
oFF
IR remote control off
(
*
) Color presets
C01
Red
C09
Green + Blue
C02
Green
C10
Green + White
C03
Blue
C11
Blue + White
C04
White
C12
Red + Green + Blue
C05
Amber
C13
Red + Green + White
C06
Red + Green
C14
Green + Blue + White
C07
Red + Blue + Amber
C15
Red + Green + Blue + White + Amber
C08
Red + White
Summary of Contents for 51918574