00106532.DOC, Version 1.0
14/16
INSTALLATION
Inserting/replacing gobos
If you want to use other shapes or patterns, or if gobos should be exchanged, please proceed as follows:
1. Disconnect the logo projector from the power supply.
2. Unscrew the two screws that hold the gobo housing (Overview point 9)
counterclockwise.
3. Remove the gobo housing.
4. Unscrew the screws of the gobo holder counterclockwise. Remove the lens and
the retainer ring. Insert/replace the gobo. Replace the lens and the retainer ring,
then retighten the two screws clockwise.
5. Slide the gobo holder back into place, and secure the housing with two screws.
DANGER!
Install the gobos or color foils with the device switched off only.
Unplug from mains before!
The LED LP-50 Logo Projector can be installed on the ground or on the wall or ceiling.
Rigging
This product is designed for overhead rigging to a wall or ceiling with the mounting bracket. It can also be
fastened to a truss using appropriate clamps. To align the unit, release the fixation screws at the mounting
bracket, adjust the desired inclination angle and retighten the fixation
screws.
WARNING – Risk of injury caused by falling objects!
Devices in overhead installations may cause severe injuries when crashing down. Make sure
that the device is installed securely and cannot fall down. Make sure that the installation
complies with the standards and rules that apply in your country, in particular EN 60598-2-17.
•
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
•
The device must be additionally secured with e.g. an appropriate safety bond. Fasten the safety bond in
such a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm. This
secondary safety attachment must be constructed in a way that no part of the installation can fall down if
the main attachment fails.
•
You must only use safety bonds and quick links complying complying with DIN 56927, shackles complying
with DIN EN 1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the carbines must
be sufficiently dimensioned and used correctly in accordance with the latest industrial safety regulations
(e. g. BGV C1, BGI 810-3).
Connection with the mains
Connect the device to the mains with the power supply cable.
The occupation of the connection cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected! If the device will be directly connected with the local power supply network, a
disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent
electrical installation.