INSTALLATION
Installing/Replacing the lamp
For the installation, you need one of the following lamps:
GE CSR575/2 SE 95V/575W GX-9.5 1000h
89107000
OMNILUX OSD 95V/575W GX-9.5 2000h 6000K
89107005
OSRAM HSR 575/60 95V/575W GX-9.5 1000h
89107010
PHILIPS MSR 575/2 95V/575W GX-9.5 1000h
89107015
OMNILUX OSR 575/2 95V/575W GX-9.5 1000h
89107017
SYLVANIA BA575/2SE NHR 575W GX-9.5 8500K
89107020
OMNILUX OSD 95V/575W GX-9.5 1000h 7200K
89107205
OSRAM HSR 575/72 95V/575W GX-9.5 1000h
89107210
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1:
Open the lampholder cover by loosening the fixation screw.
Step 2:
If replacing the lamp, remove the old lamp from the spot.
Step 3:
Insert the lamp in the lampholder.
Step 4:
Insert the lampholder and close the device.
Do not operate this device with opened housing!
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!