EUROHEAT
DISTRIBUTORS (H.B.S) LTD. March 2012
E & OE Instructions Part number IN1156 Ed. E
29
Please note:
The replacement thermocouple is universal to the Harmony and Stanford range of balanced flued gas stoves
and may differ from the one fitted to the stove.
Universal Thermocouple: Part No. MS2017
Suitable for use on the following Nestor Martin Stoves:
Harmony 35, Harmony 45.
Burner Tray Removal
1) Isolate the stove from the gas supply at the isolation valve and then remove the gas connection to the
stove.
2) Remove the log or coal effect kit from on top
of the burner matrix. Take care as the ceramics
are very fragile and are not covered under
the stoves warranty where damage has been
sustained through rough handling.
3) Remove the burner matrix from within the
stove. There may be brackets holding the base
matrix in place which may need removing or
adjusting before it can be lifted out, see page
26.
4) Remove the metal shroud from the pilot
assembly to allow access to the rear burner tray
securing bolt. See picture.
Thermocouple Replacement