EUROHEAT
DISTRIBUTORS (H.B.S) LTD. March 2012
E & OE Instructions Part number IN1156 Ed. E
10
Flue Spigot Fitting
The flue can be either top or rear exit. The flue collar (spigot) is supplied attached to the pallet on which the
stove is delivered or within the body of the stove. It will need fitting to the stove depending on which flue kit
you are using, rear exit can only be used on the rear to horizontal low-level flue kit.
Fitting Top Flue Spigot
The stove comes with the inner top flue pipe adapter fitted to the stove with a choke plate fitted below it, see
picture below. Ensure that the choke plate fitted is correct for the gas type and flue configuration to be installed,
this information is in the Balanced Flue Stove Technical Guide: IN1105. If not replace with the correct choke
plate which can be found in the bag of installation accessories.
Inside the stove in the bag of installation accessories will be the flue spigot gasket and two M5 screws to fit the
cast iron spigot. Fit the gasket as shown above and then attach the flue spigot using the two screws.
Fitting Flue Spigot and Inner Adapter Pipe
to the Rear of the Stove.
1) Remove the inner adapter pipe, see above, and
choke plate from the top of the stove. The choke
plate is not required for the rear flue option.
Choke plate
Ceramic gasket
Inner flue pipe
adapter
Choke plate