17
Power surge protection
The drill stand is able to cope with voltage spikes up to
4,000V (1-2
μs
)
.*
Power fluctuation protection
The drill stand is able to cope with voltage and frequency fluctuations ranging from:
110 Volt to 130 Volt - 45 Hz to 65 Hz
220 Volt to 240 Volt - 45 Hz to 65 Hz
When the frequency is too high or too low, so it falls outside of above mentioned range, the motor
will not start. If the frequency of the power supply falls outside the range or fluctuates strongly
during your drilling job, the motor will shut off automatically.*
* Disclaimer: Euroboor is not liable for any damage caused to the drill stand due to electrical
problems in the workplace. Above mentioned protection is not guaranteed in all cases of voltage
and frequency spikes or fluctuations. Euroboor accepts no liability when it comes to the power
surge fluctuation protection not functioning or functioning poorly.
In the situation of the motor being shut off automatically as self-protection, you should:
-
Shut off the magnet;
-
Disconnect the drill stand from the power source;
-
Fix the source of the problem, by either;
o
Making sure the issues with the power source is fixed;
o
Connect the drill stand to a different and reliable power source;
-
Continue using the drill stand as described in this user manual.
4.7 Tool lubrication
Horizontal, vertical and overhead applications
Dip the drill bit in cutting paste or apply an appropriate spray.
Make sure to use only suitable cutting lubricants. Euroboor offers a wide range of cutting lubricants
for all tool and material combinations. Proper lubrication will help you create better and faster
results, and extend the lifetime of your tools.