3.

 

Avoid accidental starting. Be sure the switch is off before plugging the stand in. Carrying a 

magnetic drill stand with your finger on the switch or plugging in a magnetic drill stand that 
has the switch on increases the change of accidents; 

4.

 

Never place hands, fingers, gloves or clothing near drilling area or rotating machine parts; 

5.

 

Remove adjusting keys or switches before turning the power on. A wrench or a key that is 

left attached to a rotating part may result in personal injury; 

6.

 

Do not overreach. Keep proper footing and balance at all times. Proper footing and balance 

enables better control of the drill stand in unexpected situations; 

7.

 

Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard 

hat and hearing protection must be used for optimal safety; 

8.

 

Always use supplied safety chain during any work on non-horizontal surfaces. Magnetic drill 

stand can release from surface.  
 

When using this magnetic drill stand, you MUST wear ear and eye protection. 

 

Use and care 

1.

 

When using the drill stand on non-horizontal surfaces, you must use cutting paste. Do not 

use oil because the oil can drip into the unit; 

2.

 

During operations, the drill you are using must be cooled and lubricated with good quality 

cutting or lubrication oil; 

3.

 

Use clamps or other practical solutions to secure and support the workpiece to a stable 

platform. Holding the workpiece by hand or against your body is unstable and may lead to 
loss of control; 

4.

 

Do not use the drill stand when the switch does not turn it on or off. Any tool that cannot be 

controlled with the switch is dangerous and must be repaired; 

5.

 

Disconnect the plug from the power source before making any adjustments, changing 

accessories or storing the tool. Such preventive safety measures reduce the risk of starting 
the tool accidentally; 

6.

 

Store your magnetic drill stand out of reach for children and other untrained persons. Tools 

are dangerous in the hands of untrained users; 

7.

 

Maintain your drill stand with care. Keep cutting tools sharp and clean. Properly maintained 

tools, with sharp cutting edges are less likely to break and are easier to control; 

8.

 

Check for misalignment of moving parts, breakage of parts and any other condition that may 

affect the operation. If you detect damage have the drill stand serviced before use. Many 
accidents are caused by poorly maintained tools; 

9.

 

Only use accessories that are recommended by Euroboor for your model. Accessories that 

are suitable for one machine may become hazardous when used on another machine. 

 
Service 

1.

 

Tool service must be performed only by qualified repair personnel. Service or maintenance 

performed by unqualified personnel could result in risk of injury; 

2.

 

When servicing a tool, use only identical replacement parts. Follow instructions in the 

maintenance section of this manual. Use of unauthorised parts or failure to follow 
maintenance instructions may create a risk of electric shock or injury; 

3.

 

Euroboor offers Armature kits containing official Euroboor spare parts suitable for your 

magnetic drilling machine.  

 

Summary of Contents for F16+

Page 1: ...r Date of purchase Don t forget to register your machine at www euroboor com register only when registered you benefit from extended warranty User manual V 1 0 EN Magnetic drill stand with standard electromagnet F16 ...

Page 2: ... the demands from the market Our vision is focused on developing innovative portable tools that add value for our customers and facilitate them in their daily work We never lose sight of sustainability time savings and cost savings Enjoy your new drill stand Before operating your new drill stand please first read all instructions You find the instructions in this manual and on the warning label on...

Page 3: ...mbly 11 3 2 Prior to use 11 4 Using the magnetic drill stand 13 4 1 Control panel 13 4 2 Installation of hand drilling machine 13 4 3 Electromagnet 14 4 4 Switching hand drilling machine on and off 16 4 5 GYRO TEC safety 16 4 6 Power surge and fluctuation protection 16 4 7 Tool lubrication 17 5 Working with drilling accessories 18 5 1 Twist drills 18 6 Maintenance 20 7 Trouble shooting 22 8 Explod...

Page 4: ... Electrical safety 1 A magnetic drill stand plug must match the outlet Never modify the plug in any way Do not us any adapter plugs 2 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose the drill stand to rain or wet conditions Water will increase the risk of electric shock ...

Page 5: ...e and may lead to loss of control 4 Do not use the drill stand when the switch does not turn it on or off Any tool that cannot be controlled with the switch is dangerous and must be repaired 5 Disconnect the plug from the power source before making any adjustments changing accessories or storing the tool Such preventive safety measures reduce the risk of starting the tool accidentally 6 Store your...

Page 6: ...mbly or construction activities on the workpiece while the machine is switched on Before switching on the power make sure all accessories have been mounted correctly Do not switch on the machine until it has been mounted and installed according to all above mentioned instructions Always use the recommended speed for the accessories and material you are working with Do not use the drill stand on th...

Page 7: ...r drilling materials with a magnetisable surface using twist drills in a weather protected environment using the application tools and accessories recommended by Euroboor The drill stand can be used horizontally vertically or overhead 2 2 Description and features image 2 1 1 Adapter ring 2 Tool holder 3 Feed handle 4 Magnet LED indicator 5 Motor switch 6 Magnet switch 7 Electromagnet ...

Page 8: ...s 1 x safety gloves 2 4 Serial number The serial number is mentioned on the machine two times engraved on the frame and engraved on the magnet Additional serial no stickers are provided with the machine for your administration The serial number will help you your dealer and Euroboor to validate and identify the machine For example 0161909001 breaks down to 016 19 09 001 Machine series Year of manu...

Page 9: ...al and specifically the General safety instructions and Specific safety information Wear ear protection Use ear protection during operation Wear eye protection Use eye protection during operation Danger warning caution Read and apply the information in the adjacent text European conformity symbol Confirms the conformity of the magnetic drilling machine with the directives of the European Community...

Page 10: ...at no load 2 7 Environmental Separate collection This product must not be disposed of with normal household waste Separate collection of used products and packaging allows materials to be recycled and used again Re use of recycled materials helps prevent environmental pollution and reduces the demand for raw materials Local regulations may provide for separate collection of electrical products fro...

Page 11: ...the magnet is level clean and rust free Remove any varnish or primer When working on materials that are not magnetisable suitable fixation devices obtainable as accessories from Euroboor e g suction plate vacuum plate or pipe drilling machine must be used When working on steel materials with a material thickness of less than 6 mm 1 4 the workpiece must be reinforced with an additional steel plate ...

Page 12: ...available at Euroboor or your Euroboor dealer Extension cable If an extension cable is required use an approved 3 core extension cable suitable for the power input of this tool see technical data The minimum conductor size is 1 5 mm the maximum length is 30 meter When using a cable reel always unwind the cable completely Useful tips Try a few simple projects using scrap material until you develop ...

Page 13: ...hand drilling machine 1 Measure the collar of the hand drilling machine you want to place in the drill stand The drill stand is suitable for use with Ø 43 mm 1 11 16 Ø 38 mm 1 1 2 or Ø 33 mm 1 5 16 collars 2 Loosen the bolt on front of the tool holder slightly Do not remove the bolt 3 Prepare the tool holder for the hand drilling machine a Ø 43 mm collar no insert b Ø 38 mm collar insert only the ...

Page 14: ... in the power socket of the magnetic drilling stand correctly and tightly 9 Make sure the power cable of the hand drilling machine stays clear of the general drilling area image 4 2 image 4 3 4 3 Electromagnet Make sure the magnetic drill stand is placed on a smooth clean level and solid surface without any objects or debris to guarantee maximum adhesion The workpiece must at least be 6 mm 1 4 thi...

Page 15: ...the magnet press the red magnet switch The magnet switch will be lit red The LED indicator lights up GREEN when generated magnetic force is sufficient 3 To deactivate the magnet press the same switch again WARNING Do not use this drill stand when LED indicator is RED Magnet may not generate sufficient attachment force We want to point out that above mentioned precautions and indicators do not guar...

Page 16: ...nces such as Sudden loss of magnetic force while in operation Excessive vibration caused by incorrect drilling procedure worn out cutting tools etc Sudden displacement of the workpiece to which the drill stand is attached By the power shutting off automatically risk of damaging or hurting the drill stand tools workpiece and operator is reduced Every time the power is turned on the drill stand s el...

Page 17: ...tage and frequency spikes or fluctuations Euroboor accepts no liability when it comes to the power surge fluctuation protection not functioning or functioning poorly In the situation of the motor being shut off automatically as self protection you should Shut off the magnet Disconnect the drill stand from the power source Fix the source of the problem by either o Making sure the issues with the po...

Page 18: ...ult 1 Install the drill bit according to original instructions of your hand drill 2 Precisely mark the center of the hole 3 Place the magnetic drill stand in the correct position by letting the tip of the twist drill meet the marked center of the hole 4 Switch on the magnet and verify that the drill is in the right position and that the drill stand is pushed tight against the work piece 5 Make sur...

Page 19: ... material 10 Turn the feed handles to put the drill stand in highest position and switch off the power supply 11 Remove the burrs metal chips and clean the drill bit and surface without getting injuries Caution The metal drill chips can be sharp and very hot ...

Page 20: ... chemicals for cleaning the non metallic parts of the tool These chemicals may weaken the materials used in these parts Use a cloth dampened only with water and mild soap Never let any liquid get inside the tool never immerse any part of the tool into a liquid Operation of the drill stand The drill stand s operation must be checked to ensure that all components are working correctly Replace any de...

Page 21: ...ely in the dove tail guideway but does not allow the motor to wobble Repair modification and inspection Repair modification and inspection of Euroboor Magnetic drill stands must be done by Euroboor or an Euroboor authorised dealer The spare parts list will be helpful if presented with the drill stand to the Euroboor dealer for service when requesting repair or other maintenance Euroboor drill stan...

Page 22: ...t Guide is set too tight Guide is dry needs to be greased Guide gear rack rotation system dirty or damaged Insufficient magnetic force Damaged or defective wiring Bottom of magnet not clean and dry Bottom of magnet not flat Workpiece is not bare metal Workpiece is not clean or flat Workpiece is less than 6 mm too thin Defective control unit Defective magnet Frame under voltage Damaged defective wi...

Page 23: ...23 8 Exploded views spare parts list 8 1 Exploded views ...

Page 24: ...24 ...

Page 25: ...rew M4 x 10 4 24 020 0182 Grounding screw washer nut 1 25 26 27 020 0036 Main cable 220V EU 1 020 0036 AU Main cable Australia 020 0036 UK Main cable UK 220v 020 0036 UK 110 16A Main cable UK 110v 16A 020 0036 USA Main cable USA 020 0031 Coupling nut PG11 main cable 1 No Part no Description Qty 24 020 0037 Cable clamp complete 1 28 29 30 032 1008Z Control unit 110 220 Volt 1 31 020 0017 Fuse 5 x 2...

Page 26: ...26 8 3 Wiring diagram ...

Page 27: ...This 12 month period can be extended to 24 months in total by registering the product on our website https euroboor com support register Service To maximise the lifetime of your Euroboor machine always use service and parts from an official Euroboor distribution channel Whenever in need of such always contact original point of sales or if no longer existent the distributor of Euroboor products in ...