12 ALARMS OF THE STOVE
In the event that a malfunction occurs, the board intervenes and signals the irregularity, lighting the LED
Alarm (Alarm LED on) and producing acoustic signals (if the buzzer is activated).
There are the following alarms:
Alarm origin
Display view
Energetic Black-out
AL 1 ALAR AL 1 BLAC-OUT
Probe temperature smokes
AL 2 ALAR AL 2 PROBE EXHAUST
Fumes overheating
AL 3 ALAR AL 3
HOT EXHAUST
Encoder fumes failure
AL 4 ALAR AL 4 FAN FAILURE
Firing failure
AL 5 ALAR AL 5 NO LIGHTIN-
Pellet absence
AL 6 ALAR AL 6 NO PELLET
Overheating thermal safety
AL 7 ALAR AL 7 SAFETY THERMAL
No depression
AL 8 ALAR AL 8 FAILURE DEPRESS
Each alarm condition causes the immediate turning off of the stove
The alarm state is reached after the time PR11, EXCEPT THE ALARM OF BLAC-OUT, and can be reset by
pressing and holding the button P3. Whenever an alarm is reset, a turning off phase of the stove is initiated
for safety. During the alarm phase, the alarms LED will always be on (alarm LED on) and when enabled the
buzzer, it will sound intermittently. If you fail to reset the alarm, the stove will shut down anyway, always
displaying the alarm message.
12.1
Energetic Black out
During the working status of the stove, electricity may miss. When it is restarted, if the period of the black
out is lower than the parameter PR48, the stove restarts on WORK mode, otherwise the alarm is activated.
The message " AL 1 ALAR AL 1 BLAC-OUT " will pass on the display (
Figure 20
) and the stove goes off.
Figure 20
Al 1 alar al 1 blac-out
Summary of Contents for Monviso
Page 1: ...Use and maintenance manual for pellet stove...
Page 47: ...Below there is an example of installation of ducted stove in a home...
Page 48: ...17 Notes...