Outdoor Unit:
AE52AC3/ACL3
AE52AH3
Compressor
Type
Compressor model
Nominal output
W
Compressor oil…Amount
cc.
Coil resistance (Ambient temp. 25°C)
Ω
Safety devices
Type
Overload relay
Operating Temp. Open
°C
Close
°C
Fan & Fan Motor
Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Nominal output
W
Coil resistance (Ambient temp. 20 °C )
Ω
Ω
Safety devices
Type
Operating temp. Open
°C
Close
°C
Run capacitor
µF
VAC
Heat Exch. Coil
Coil
Rows
Fin pitch
mm
Face area
m
2
External Finish
Internal protector
CS01D350H03(SDR-S400)
120
-
-
Operating amp.(Ambient temp.25°C)
YYK85E-6…1
1…. Ø 460
130
-
450
main:147
4
aux:165
6…815
75
5500(at 220V)
MEL 56…1300
3,59
Rotary (Hermetic)
NN21YDAMT
0,542
Acrylic baked-on enamel finish
Propeller
thermistor
Aluminium plate fin / Copper tube
2
1,74
9