Euro-Line AE52AC Service Manual Download Page 2

IMPORTANT!
Please read before installation

This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important  to install or
service the system so that it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical  codes.
• Pay close attention to all warning and caution notices given in

this manual.

•The unit must be supplied with a dedicated electrical line.

This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.

If necessary, get help

These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.

In case of improper installation

The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.

SPECIAL PRECAUTIONS

• During installation, connect before the refrigerant system and

then the wiring one; proceed in the reverse orden when removing
the units.

When wiring

ELECTRICAL

SHOCK CAN CAUSE SEVERE

PERSONAL INJURY OR DEATH. ONLY A QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.

• Do not supply power to the unit until all wiring and tubing are

completed or reconnected and checked, to ensure the grounding.

• Highly dangerous electrical voltages are used in this system.

Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause

accidental injury and death

.

Ground the unit 

following local electrical codes.

• The Yellow/Green wire cannot be used for any connection

different from the ground connection.

• Connect all wiring tightly. Loose wiring may cause overheating

at connection points and a possible fire hazard.

• Do not allow wiring to touch the refrigerant tubing, compressor,

or any moving parts of the fan.

• Do not use multi-core cable when wiring the power supply and

control lines. Use separate cables for each type of line.

When transporting

Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.

When installing...
... In a ceiling or wall

Make sure the ceiling/wall is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.

... In a room

Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to walls
and floors.

... In moist or uneven locations

Use a raised concrete base to provide a solid level foundation for
the outdoor unit.
This prevents damage and abnormal vibrations.

... In area with strong winds

Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.

... In a snowy area (for heat pump-type systems)

Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.

When connecting refrigerant tubing

• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare

and union tubes before connecting them;  screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.

• Check carefully for leaks before starting the test run.

NOTE:

Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.

When servicing

• Turn the power OFF at the main power board  before opening

the unit to check or repair electrical parts and wiring.

• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no

metal scraps or bits of wiring have been left inside the unit being
serviced.

• Ventilate the room during the installation or testng the refrigeration

system; make sure that, after the installation, no gas leaks are
present, because this could produce toxic gas and dangerous
if in contact with flames or heat-sources.

WARNING

CAUTION

WARNING

2

Summary of Contents for AE52AC

Page 1: ...UTDOOR UNIT AE52AC ACL AE52AH AE52AC3 ACL3 AE52AH3 SPLIT SYSTEM AIR CONDITIONER Model No Product Code No AE52AC 387031044 AE52AC3 387031045 AE52AH 387031049 AE52AH3 387031050 AE52ACL 387031057 AE52ACL3 387031058 0 8180 462 0 08 2005 ...

Page 2: ...ring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line When transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminium fins...

Page 3: ...her Component specifications 10 3 DIMENSIONAL DATA 11 4 REFRIGERANT FLOW DIAGRAM 12 5 PERFORMANCE DATA 14 5 1 Performance Charts 14 5 2 Cooling Capacity 15 5 3 Heating Capacity 16 6 ELECTRICAL DATA 17 6 1 Electrical characteristics 17 6 2 Electric Wiring Diagram 19 6 3 System Wiring Diagram 21 Table of Contents 3 ...

Page 4: ...s AE52ACL AE52ACL3 Cooling Maximum Minimum 46 C D B 10 C D B 10 C D B 32 C D B 23 C W B 21 C D B 15 C W B 24 C D B 18 C W B 9 C D B 10 C W B Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Heating Maximum Minimum 27 C D B 4 ...

Page 5: ...rrow tube mm in tube diameter Wide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks Rating conditions are Cooling Indoor air temperature 27 C D B 19 C W B Outdoor air temperature 35 C D B 24 C W B Heating Indoor air temperature 20 C D B O...

Page 6: ... mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks Rating conditions are Cooling Indoor air temperature 27 C D B 19 C W B Outdoor air temperature 35 C D B 24 C W B Heating Indoor air temperature 20 C D B Outdoor air temperature 7 C D B 6 C W B ...

Page 7: ...e mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks Rating conditions are Cooling Indoor air temperature 27 C D B 19 C W B Outdoor air temperature 35 C D B 24 C W B Heating Indoor air temperature 20 C D B Outdoor air temperature 7 C D B 6 C W B...

Page 8: ... poles rpm 230 V High Nominal output W Coil resistance Ambient temp 20 C Ω Ω Safety devices Type Operating temp Open C Close C Run capacitor µF VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish 0 542 Acrylic baked on enamel finish Propeller thermistor Aluminium plate fin Copper tube 2 1 74 Rotary Hermetic PA200X2CS 4KU1 6 815 75 4860 at 220V VG74 750 C R 1 85 C S 2 62 130 450 ...

Page 9: ...High Nominal output W Coil resistance Ambient temp 20 C Ω Ω Safety devices Type Operating temp Open C Close C Run capacitor µF VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish Internal protector CS01D350H03 SDR S400 120 Operating amp Ambient temp 25 C YYK85E 6 1 1 Ø 460 130 450 main 147 4 aux 165 6 815 75 5500 at 220V MEL 56 1300 3 59 Rotary Hermetic NN21YDAMT 0 542 Acrylic b...

Page 10: ... Coil Rating Contact rating A Coil resistance Ω AE52AC AE52ACL AE52AH Power Relay Type Coil Rating Contact rating A Coil resistance Ω AE52ACL AE52ACL3 Low ambient kit Rating Setpoint MPa 10K 2 SHF 9H 35U Valve AC 220 240V 50Hz 7W 1500 Positive phase ON Negative phase OFF 20 1000 10 ALPHA 8 1 AC 380 V 3 PHASE 50 Hz AC 240 V 2 A AC 230V 50 Hz 2 4 CJX9B 25S 01TH AC 220 230V 50Hz 60Hz 1100 10 RGE Z1L6...

Page 11: ...3 DIMENSIONAL DATA Outdoor Unit AE52AC ACL AE52AH AE52AC3 ACL3 11 ...

Page 12: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit Outdoor Unit AE52AC ACL AE52AC3 ACL3 12 ...

Page 13: ...Indoor Unit Outdoor Unit AE52AH AE52AH3 13 ...

Page 14: ...5 PERFORMANCE DATA 5 1 Performance charts AE52AC ACL AE52AH AE52AC3 ACL3 AE52AH3 Cooling Characteristics Heating Characteristics 7 7 14 ...

Page 15: ...W52AL 220 240V 50Hz RATING CAPACITY 5 50 kW moisture removal 1 8 l h POWER INPUT 1 69 kW max power input 2 26 kW AIR FLOW RATE 930 m h RATING CONDITIONS Cooling Indoor air temperature 27 C D B 19 C W B Outdoor air temperature 35 C D B 24 C W B NOTE Data related to matching with AW52AL 15 ...

Page 16: ...e chart indicates the following rating condition Indoor 20 C D B Outdoor 7 C D B 6 C W B 2 The above chart includes the weighted deicing influence 0 20 40 60 80 100 120 15 10 5 0 5 10 15 20 25 Outdoor temperature C W B Heating capacity ratio 16 ...

Page 17: ...ns Indoor Air Temperature 27 C D B 19 C W B Outdoor Air Temperature 35 C D B HEATING performance at Rating conditions Running Amps A Power input Kw Rating Conditions Indoor Air Temperature 20 C D B Outdoor Air Temperature 7 C D B 6 C W B Full load conditions Running Amps A 230V 1 Phase 50 Hz 230V 1 Phase 50 Hz Complete Unit Complete Unit 7 50 1 690 7 10 1 6 11 0 17 ...

Page 18: ...re 27 C D B 19 C W B Outdoor Air Temperature 35 C D B HEATING performance at Rating conditions Running Amps A Power input Kw Rating Conditions Indoor Air Temperature 20 C D B Outdoor Air Temperature 7 C D B 6 C W B Full load conditions Running Amps A 4 30 Complete Unit Complete Unit 3 06 1 690 3 10 1 6 380V 3 Phase 50 Hz 380V 3 Phase 50 Hz 18 ...

Page 19: ...6 2 Electric Wiring Diagram OUTDOOR UNIT AE52AC AH OUTDOOR UNIT AE52ACL 19 ...

Page 20: ...OUTDOOR UNIT AE52AC3 AH3 OUTDOOR UNIT AE52ACL3 20 ...

Page 21: ...6 3 System Wiring Diagram AE52AC ACL AE52AH AE52AC3 ACL3 AE52AH3 21 ...

Page 22: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it ...

Reviews: